The lightning flash with an arrowhead symbol

within an equilateral triangle is intended to alert 

the user to the presence of uninsulated 

dangerous voltage within the product's enclosure 

that may be of sufficient magnitude to constitute

a risk of electric shock to persons.

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED

SERVICE PERSONNEL

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The exclamation point within an equilateral triangle 
is intended to alert the user to the presence of 
important operating and maintenance (servicing) 
instructions in the literature accompanying 
the product.

REGULATORY INFORMATION : FCC Part 15

WARNING - Do not install this equipment in a confined
space such as a bookcase or similar unit.

Disposal of your old appliance
1. When this crossed-out wheeled bin symbol

    is attached to a product it means the product

    is covered by the European Directive 

    2002/96/EC
2. All electrical and electronic products should

    be disposed of separately from the municipal

    waste stream via designated collection facilities

    appointed by the government or the local 

    authorities
3. The correct disposal of your old appliance

    will help prevent potential negative conse-

    quences for the environment and human 

    health
4. For more detailed information about disposal

    of your old appliance, please contact your

    city office, waste disposal service or the shop

    where you purchased the product.

To disconnect power from the mains, pull out the main
cord plug. When installing the product, ensure that the 
plug is easily accessible.

WARNING - Wiring methods shall be in accordance with
the National Electric Code, ANSI/NFPA 70.

WARNING - To reduce a risk of fire or electric shock, do
not expose this product to rain or moisture.
CAUTION - This installation should be made by a qualified
service personrel and should conform to all local codes.
CAUTION - To avoid electrocal shock, do not open the 
cabinet. Refer servicing to qualified personnel only.

CAUTION - The apparatus should not be exposed to
water (dripping or splashing) and no objects filled with
liquids, such as vases, should be placed on the apparatus.

WARNING - This is a class A product. In a domestic
environment this product may cause radio interference 
in which case the user may be required to take adequate
measures.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION :

FCC WARING - This equipment may generate or use 
radio frequency energy. Changes or modifications to 
this equipment may cause harmful interference unless 
the modifications are expressly approved in the instruction

manual. The user could lose the authority to operate this 
equipment if an unauthorized change or modification is made.

This equipment has been tested and found to comply with

the limits for a Class A digital device, pursuant to Part 15

of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interference when

the equipment is operated in a commercial environment

This equipment generates, uses, and can radiate radio

frequency energy and, if not installed and used in accordance

with the instruction manual, may cause harmful interference 

to radio communications. Operation of this equipment 

in a residential area is likely to cause harmful interference

in which case the user will be required to correct the 

interference at his own expense.
-      A suitable conduit entries, knock-outs or glands shall

       be provided in the cable entries of this product in the

       end use.

-     Holes in metal, through which insulated wires pass,

       shall have smooth well rounded surfaces or shall 

       be provided with brushings.

03

Summary of Contents for MB-H208

Page 1: ...Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use The design and specifications are subject to change without prior noti...

Page 2: ...ce a risk of fire or electric shock do not expose this product to rain or moisture CAUTION This installation should be made by a qualified service personrel and should conform to all local codes CAUTI...

Page 3: ...lar surface This product should not be placed in a built in installation such as a bookcase or rack unless proper ventilation is provided and the manufacturer s instructions have been adhered to 8 Do...

Page 4: ...NECTIONS MENU OPERATION NETWORK MAIN MENU FOCUS EXPOSURE WHITE BALANCE IMAGE INTELLIGENCE 7P 8P 9P 10P 12P 13P 14P 15P 17P 18P 19P 22P 23P 25P 1 3 Panasonic CMOS sensor x20 x30 Optical Zoom Full HD Re...

Page 5: ...ENTS SYSTEM CONFIGURATION Optional Remote Controller CAMERA MANUAL CABLE Not used Far Right Tele Up Menu Set Wide Down Near Left RS485 RS485 RS485 DVR NVR Keyboard TV Monitor VIDEO VIDEO VIDEO HD SDI...

Page 6: ...a 1 IEEE802 3af POE LAN 2 MICRO SDCARD MEMORY 3 SPEAKER OUT 4 MIC IN 5 OSD CONTROL 6 HD SDI 7 CVBS OUT 8 HDMI OUT 9 IP RESET 10 POWER LED 11 I O Ports 11 1 RS485 11 2 RS485 11 3 Motion Detection Out 1...

Page 7: ...ler of RS 485 format Protocol Pelco D 2400 supported Motion Detection Out When the motion detection function is working DC3 3V is outputed to OUT pin and GND pin Day Night input Day Night mode of the...

Page 8: ...e Moves the cursor to the left Use this button to select or adjust the parameters of the selected item The parameter changes each time this button is pressed Set button Executes selections and display...

Page 9: ...displayed where 7 camera functions can be selected To the push of each main menu selection the sub menu is displayed If you want save the menu select SAVE If you want not save the menu select EXIT Af...

Page 10: ...9 x21 x23 x25 x28 x32 ZOOM PRESET Select zoom preset PRESET Select Zoom preset number 1 5 MODE OFF ON ON Adjust the Zoom Position AUTO 1 0m ONE PUSH OFF 7 EXPOSURE MENU FOCUS EXPOSURE WHITE BAL IMAGE...

Page 11: ...SIZE Adjust the window size Can t use WDR and BLC at the same time When WDR On BLC is Off And when BLC is On WDR is Off BLC doesn t work in Manual Exposure Mode DAY NIGHT Select Day Night MODE AUTO E...

Page 12: ...DNR MIRROR SHARPNESS ACE DEFOG FREEZE GAMMA BACK SAVE DFLT MIDDLE OFF OFF OFF OFF 0 55 7 WHITE BALANCE MENU FOCUS EXPOSURE WHITE BAL IMAGE INTELLIGENCE SPECIAL FUNC DISPLAY EXIT SAVE DFLT WHITE BAL MO...

Page 13: ...OFF ON GAMMA Select GAMMA 0 45 0 55 0 65 0 75 24 25 IMAGE INTELLIGENCE INTELLIGENCE MENU FOCUS EXPOSURE WHITE BAL IMAGE INTELLIGENCE SPECIAL FUNC DISPLAY EXIT SAVE DFLT INTELLIGENCE PRIVACY MOTION DIS...

Page 14: ...ode OFF ON RANGE Setting the image compensation range 10 20 30 FILTER Setting the sensitivity to hold DIS function in worst case LOW MIDDLE HIGH AUTO C Setting Auto Centering mode OFF HALF FULL OFF OF...

Page 15: ...SPECIAL FUNC DISPLAY EXIT SAVE DFLT DISP SEL Select display item OFF ON ID OFF ON TITLE OFF ON ZOOM RATIO OFF ON SYSTEM MSG OFF ON MD Alarm SET TITLE Select camera title menu Text edit max 40 charact...

Page 16: ...V 2 12M Pixels Progressive Scan Internal Digital 1080p 30 25 fps Analog 700TVL Color 0 5 lux BW 0 1lux Color DSS 0 125 lux BW DSS 0 025 lux HD SDI HDMI CVBS more than 50dB AGC off Lens type Zoom Rati...

Page 17: ...s OFF WDR BLC Auto Day Night Ext in Auto One Push Manual Indoor Outdoor HLC DNR Mirror Sharpness ACE Defog Freeze Gamma Off On Night Only Auto Off Low Middle High Model Mirror Sharpness ACE Defog Free...

Page 18: ...Humidity 0 RH 90 RH 10 50 Humidity 0 RH 90 RH Design and specifications are subject to change without notice Design and specifications are subject to change without notice NETWORK Ethernet Video Comp...

Page 19: ...ON DETECTION mode is turned on Please check if the MD Sensitivity is too high Please check the setting of the MD AREA The WDR function is not working Please check if the WDR Level is too low Please ch...