background image

3

Ventilation requirements
Note: see convector instructions if being installed within a Wonderfire convector box for
ventilation requirements.

GB 

A permanent ventilation grille
of fixed design and having a
minimum free area of 100cm

2

must be fitted with direct
access to outside air to room.

IE

Ventilation must be in
accordance with IS 813 1996
(as amended)

Please note: This appliance is not
supplied with a decorative
firefront. A slotted firefront with a
minimum free area as shown in
figure 2 must always be used.

Operation of the fire

This fire may be controlled manually, by use of a gas valve mounted on the appliance.
The flame settings may also be controlled by means of the remote control handset. To
prevent accidental operation of the fire, we recommend that the fire be switched off
when not in use.

To Light the Pilot

Please note:- The fire must be lit manually.
Ensure that the pilot burner control knob is in the OFF position (1). Depress the
control knob and turn anti-clockwise to the ignition position (2) to activate the piezo
ignition system. A ‘click’ will be observed, and the pilot should light. Hold the knob in
this position (keeping it depressed) for ten seconds to allow the flame supervision
device to establish.

Gas Valve

Figure 4

5

Main Burner
Control Knob

4

3

2

1

Figure 3

Pilot Burner
Control Knob

High Flame

Low Flame/Pilot

Remote Control
Handset

6

Figure 2

Summary of Contents for airflame excel mk.3 ac 18xl rc

Page 1: ...te control AF 18XL RC 9500374 AC 18XL RC 9500375 USERS MANUAL Patent applied for 9860380 03 Please leave these Instructions with the user This Appliance is for use in the United Kingdom GB and the Rep...

Page 2: ...If the appliance shuts down after a period of operation for no apparent reason then stop using the appliance until the installation and the appliance have been thoroughly checked by a competent perso...

Page 3: ...gas valve mounted on the appliance The flame settings may also be controlled by means of the remote control handset To prevent accidental operation of the fire we recommend that the fire be switched...

Page 4: ...f a setting between LOW 4 and HIGH 5 is required then the control knob may be turned to this position Note We recommend you use the appliance at a low setting for the first few hours of use to reduce...

Page 5: ...ace Remove cover from rear of handset remove and discard old battery Replace battery and refit cover See figure 5 Receiver Unit The receiver valve is powered by 4xAA batteries which should be replaced...

Page 6: ...armful to the surface The coals should normally require no maintenance between the annual inspection described in the installation and maintenance instructions However if your fire is used frequently...

Page 7: ...ffect it is important that the coals are evenly spaced and sit 10 15mm from each other Next take five random shaped coals and position as shown in figure 11 This second row of coals should rest on top...

Page 8: ...e 13 a b b c Figure 14 c Finally take the three remaining random shaped coals Place one in the centre of the matrix position a place the other two next to it position b as shown in figure 14 To comple...

Page 9: ...GUARANTEE Every Wonderfire product is warranted for a period of twelve months against manufacturing faults Any part found to be of substandard quality will be replaced free of charge by your supplier...

Page 10: ...rvice department If you require your fire to be serviced or in the unlikely event that it should require repair due to a manufacturing defect then call Wonderfire service department on 0121 386 203 qu...

Reviews: