
44
TGB-40/60 Maintenance instructions
Combustion
chamber pot
Remove the pot
• Release the nut inside the combustion chamber, if
necessary counter-lock the screw.
• Remove the pot.
Combustion chamber pot inside the heating water heat
exchanger
• With the burner, push the insulation from the bottom up
and out.
To do this, invert the heat exchanger on the floor and
carefully push down from the top.
Pushing out the insulation with the burner
Two part insulation pushed out of the heat exchanger