background image

6

Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

Pro 24"

(610)

Deep Wall Ventilation Hood

M O D E L P W 6 6 2 4 1 8 ( R )

Ducting for Pro 24" (610)
deep wall hoods.

DUCTWORK INSTALLATION 

THROUGH ROOF 

24"

(610)

DEPTH OF HOOD

ROOF CAP OR REMOTE BLOWER

10"

(254) ROUND DUCT

SOFFIT OR CABINET

OR DUCT COVER  

NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.

VERTICAL DISCHARGE 

TRANSITION

22

1

/

4

"W x 9"D TO 10"

 

ROUND

10"H (INCLUDING FLANGES)

30"

TO

36"

(762–914) 

COUNTERTOP 

TO BOTTOM OF 

VENTILATION HOOD

36"

(914)

STANDARD 

FLOOR TO 

COUNTERTOP 

HEIGHT

18"

(457)

HEIGHT OF HOOD

WALL HOOD

D U C T I N G C O N S I D E R A T I O N S

Wolf Pro 24" (610) deep wall hoods are shipped

without the blower assembly. Internal, in-line

and remote blower assemblies are available.

IMPORTANT NOTE:

Install this ventilation hood

only with a Wolf blower.

Pro 24" (610) deep wall hoods have a vertical

discharge. A horizontal discharge kit is available

as a sales accessory.

The hood will operate most efficiently when

ductwork does not exceed 50' (15 m) in length.

Local building codes may require the use of

make-up air. Consult your local HVAC profes-

sional for specific requirements in your area.

IMPORTANT NOTE:

Wolf Pro 24" (610) deep

wall hoods must be vented to the outside. Use

only metal ductwork.

Refer to the illustration below for ducting

considerations for Pro 24" (610) deep wall

hoods.

Summary of Contents for PW662418

Page 1: ...d sealed burner rangetops Pro wall ventilation hoods are recommended for use with all Wolf cooking appliances For optimal perform ance a Pro 27 686 deep wall hood is recommended for use with ranges an...

Page 2: ...hemmed edges and sides and hand finished craftsmanship Recessed easy access controls Infinite speed blower control Heat sentry feature automatically turns unit on when heat is sensed and automaticall...

Page 3: ...shell only 146 lbs 66 kg Horizontal discharge applications require a horizontal discharge kit Specifications are subject to change without notice B L O W E R O P T I O N S 1200 CFM Internal Blower 81...

Page 4: ...h of Hood 66 1676 Overall Height of Hood 18 457 Overall Depth of Hood excluding rail 24 610 Countertop to Bottom of Hood 30 762 to 36 914 Location of Electrical Within shaded area See Installation Ins...

Page 5: ...Wolf Pro wall hoods are shipped without a blower assembly Internal in line or remote blower assemblies are available Blower options also vary with the volume of air that needs to be moved and the len...

Page 6: ...OOD WALL HOOD D U C T I N G C O N S I D E R A T I O N S Wolf Pro 24 610 deep wall hoods are shipped without the blower assembly Internal in line and remote blower assemblies are available IMPORTANT NO...

Page 7: ...blowers are mounted in between the hood and the exterior of the home Remote blowers can be mounted on the roof or in some cases on an exterior wall Refer to the illustra tions below for dimensions of...

Page 8: ...18 1100 CFM In Line BLOWER 110IL 808332 All 24 610 Deep Wall Hoods 600 CFM Remote BLOWER 60REM 801640 PW302418 900 CFM Remote BLOWER 90REM 801641 PW302418 PW362418 PW422418 PW482418 PW542418 1200 CFM...

Reviews: