5
Dimensions in parentheses are in
millimeters unless otherwise specified.
I N S TA L L AT I O N
I N S T R U C T I O N S
A C C E S S O R I E S
Optional acces-
sories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
the Showroom
Locator section of
our website,
wolfappliance.com.
R E C I R C U L A T I N G K I T
If you are installing the accessory recirculating
kit, refer to the instructions included with the
kit before installing the hood. Accessory kits
are available through your Wolf dealer.
H O R I Z O N T A L D I S C H A R G E K I T
Pro low-profile wall hoods come standard
from the factory with horizontal or vertical
discharge. If a horizontal discharge is needed
for installation of a 24" (610) or 27" (686) deep
wall hood, an accessory horizontal discharge
kit is required. Refer to the instructions
included in the kit for complete mounting and
blower options. Accessory kits are available
through your Wolf dealer.
I N S TA L L AT I O N
C O N S I D E R A T I O N S
IMPORTANT NOTE:
Wolf recommends that
the Pro wall ventilation hood be installed
30" (762) to 36" (914) above the countertop.
Rail option (R) wall hoods come with a classic
stainless steel decorative rail and stand-offs.
Optional platinum or brass rails are available
to match Wolf dual fuel range bezels. Contact
your Wolf dealer for details.
E L E C T R I C A L R E Q U I R E M E N T S
Wolf Pro wall ventilation hoods require a
separate, grounded 110/120 V AC, 60 Hz power
supply. The service should have its own 15
amp circuit breaker. Locate the electrical
supply within the shaded area shown in the
Installation Specifications illustration on
page 7.
You must follow all National Electrical Code
regulations. In addition, be aware of local
codes and ordinances when installing your
service.
D U C T C O V E R
If you are installing a Wolf duct cover with the
Pro wall hood, refer to instructions on page 18
before installing the hood.