14
W O L F
P R O WA L L V E N T I L AT I O N
H O O D S
30"
TO
36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
18"
(457)
HEIGHT OF HOOD
WALL HOOD
DUCTWORK INSTALLATION
THROUGH ROOF
36"
(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
27"
(686)
DEPTH OF HOOD
10"
(254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.
TRANSITION
22
1
/
4
"W x 9"D TO 10" ROUND
10"H (INCLUDING FLANGES)
ROOF CAP OR REMOTE BLOWER
VERTICAL DISCHARGE
Ducting for 27" (686) deep wall hoods
2 4 " ( 6 1 0 )
A N D
2 7 " ( 6 8 6 )
W A L L H O O D S
S T E P 1 : I N S T A L L D U C T W O R K
Always install a roof or wall cap if you are not
installing a remote blower. Connect 10" (254)
round metal ductwork to the cap and work
back towards the hood. Use duct sealing tape
on joints between ductwork sections.
Wolf Pro 24" (610) and 27" (686) deep wall
hoods come standard with a backdraft damper
included in the transition assembly. Local
codes may require the use of an additional
backdraft damper. Contact your local HVAC
professional for specific requirements. In cold
weather installations, a backdraft damper is
necessary to minimize the backflow of cold air
into the room.
Local building codes may require the use of
make-up air. Consult your local HVAC profes-
sional for specific requirements in your area.
To reduce the risk of fire and electric
shock, install this ventilation hood only
with a blower manufactured by Wolf.
Blower model numbers are listed on
page 24.