Pro Wall Hood Specifications
9
wolfappliance.com/specs
Discharge Specifications
24" AND 27" DEEP WALL HOODS
The illustration below provides dimensions for vertical
discharge for 24" (610) and 27" (686) deep wall hoods.
These dimensions are critical for proper installation.
Dimension A in the illustration will vary with the width of
the hood. Refer to the chart below.
An optional horizontal discharge kit is available through
your authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com.
24" and 27" Deep Wall Hoods
WIDTH OF HOOD
A
30"
(762)
14
3
/
4
"
(375)
36"
(914)
17
3
/
4
"
(451)
42"
(1067)
*
20
3
/
4
"
(527)
48"
(1219)
*
23
3
/
4
"
(603)
54"
(1372)
*
26
3
/
4
"
(679)
60"
(1524)
*
29
3
/
4
"
(756)
66"
(1676)
*
32
3
/
4
"
(832)
Duct Cover
IMPORTANT NOTE:
If an optional duct cover is to be used
with any pro wall hood, it must be attached before
installing the hood. Installing a duct cover will impact all
aspects of the hood installation including hood location,
ducting, electrical placement and the mounting surface.
DUCT COVER INSTALLATION
•
Remove all screws from the front edge of the back
panel on the top of the wall hood. Leave the two
screws on the sides, there is a relief in the duct cover
for them.
•
Attach the duct cover from the inside of the hood
through the filter opening using the screws provided.
•
Leave screws partially loose until all screws are
installed. Check alignment of the duct cover with the
hood and tighten the four corner screws to secure the
duct cover. Tighten all remaining screws.
•
Proceed with installation of the wall hood.
DUCT COVER
MOUNTING
SCREWS
Duct cover installation.
9"
(229)
5
5
/
8
"
(143)
TO CENTER
OF TRANSITION
A
TO
CENTER OF
TRANSITION
24" and 27" deep wall hoods—vertical discharge.