background image

Pro Wall Hood Specifications

9

wolfappliance.com/specs

Discharge Specifications

24" AND 27" DEEP WALL HOODS

The illustration below provides dimensions for vertical

discharge for 24" (610) and 27" (686) deep wall hoods.

These dimensions are critical for proper installation.

Dimension A in the illustration will vary with the width of

the hood. Refer to the chart below.

An optional horizontal discharge kit is available through

your authorized Wolf dealer. For local dealer information,

visit the find a showroom section of our website,

wolfappliance.com.

24" and 27" Deep Wall Hoods

WIDTH OF HOOD

A

30"

(762)

14

3

/

4

"

(375)

36"

(914)

17

3

/

4

"

(451)

42"

(1067)

*

20

3

/

4

"

(527)

48"

(1219)

*

23

3

/

4

"

(603)

54"

(1372)

*

26

3

/

4

"

(679)

60"

(1524)

*

29

3

/

4

"

(756)

66"

(1676)

*

32

3

/

4

"

(832)

Duct Cover

IMPORTANT NOTE:

If an optional duct cover is to be used

with any pro wall hood, it must be attached before

installing the hood. Installing a duct cover will impact all

aspects of the hood installation including hood location,

ducting, electrical placement and the mounting surface.

DUCT COVER INSTALLATION

Remove all screws from the front edge of the back

panel on the top of the wall hood. Leave the two

screws on the sides, there is a relief in the duct cover

for them.

Attach the duct cover from the inside of the hood

through the filter opening using the screws provided.

Leave screws partially loose until all screws are

installed. Check alignment of the duct cover with the

hood and tighten the four corner screws to secure the

duct cover. Tighten all remaining screws.

Proceed with installation of the wall hood.

DUCT COVER

MOUNTING

SCREWS

Duct cover installation.

9"

(229)

5

5

/

8

"

(143)

TO CENTER

OF TRANSITION

A

TO

CENTER OF

TRANSITION

24" and 27" deep wall hoods—vertical discharge.

Summary of Contents for Pro Wall

Page 1: ...Pro Wall Ventilation Hoods INSTALLATION GUIDE ...

Page 2: ... are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Pro Wall Ventilation Hoods 3 Installation Considerations 4 Pro Wall Hood Specifications 5 Pro Wall Hood Installation 10 Service Information 22 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date...

Page 3: ... Electrical Codes as well as all state municipal and local codes The correct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product rating plate Record the model and serial numbers before installing the ve...

Page 4: ...entilation hood be installed 30 762 to 36 914 above the countertop IMPORTANT NOTE For optimal performance in wall hood applications a pro 27 686 deep wall hood is recom mended for use with ranges and rangetops that contain a charbroiler or griddle BLOWER ASSEMBLIES Pro ventilation hoods are shipped without the blower assembly Internal in line and remote blowers are avail able through your authoriz...

Page 5: ...EPTH 12 305 Overall Dimensions LOW PROFILE WALL HOODS 30 762 36 914 42 1067 48 1219 54 1372 60 1524 AND 66 1676 WIDTHS 18 457 OVERALL HEIGHT 4 102 24 610 OVERALL DEPTH 12 305 24 610 DEEP WALL HOODS 30 762 36 914 42 1067 48 1219 54 1372 60 1524 AND 66 1676 WIDTHS 27 686 OVERALL DEPTH 12 305 18 457 OVERALL HEIGHT 4 102 27 686 DEEP WALL HOODS ...

Page 6: ...0 762 TO 36 914 TO COUNTERTOP 10 254 HEIGHT OF HOOD 22 559 DEPTH OF HOOD Installation Specifications LOW PROFILE WALL HOODS E 6 152 5 127 LOCATION OF ELECTRICAL WIDTH OF HOOD 30 762 TO 36 914 TO COUNTERTOP 18 457 HEIGHT OF HOOD 24 610 OR 27 686 DEPTH OF HOOD 24 AND 27 DEEP WALL HOODS ...

Page 7: ...vailable through your authorized Wolf dealer For local dealer infor mation visit the find a showroom section of our website wolfappliance com RECIRCULATING INSTALLATION Pro wall hoods 30 762 and 36 914 wide with an internal blower 600 CFM or less can be used in a non ducted application with a recirculating filter In this installa tion kitchen air is purified through filters and returned as clean a...

Page 8: ...s available through your authorized Wolf dealer For local dealer information visit the find a showroom section of our website wolfappliance com Low Profile Wall Hoods WIDTH OF HOOD A 30 762 143 4 375 36 914 173 4 451 42 1067 203 4 527 48 1219 233 4 603 500 CFM blower not available for these hood widths A TO CENTER OF TRANSITION 11 2 38 2 51 TO CENTER OF TRANSITION Horizontal discharge 9 229 55 8 1...

Page 9: ...ional duct cover is to be used with any pro wall hood it must be attached before installing the hood Installing a duct cover will impact all aspects of the hood installation including hood location ducting electrical placement and the mounting surface DUCT COVER INSTALLATION Remove all screws from the front edge of the back panel on the top of the wall hood Leave the two screws on the sides there ...

Page 10: ...transition included with the 500 CFM internal blower accommodates 31 4 83 x 10 254 ductwork An optional 31 4 83 x 10 254 to 8 203 round transition is available through your authorized Wolf dealer Pro 24 610 and 27 686 deep wall hoods have a vertical discharge If a horizontal discharge is necessary an accessory horizontal discharge kit is required Refer to installation instructions provided with th...

Page 11: ...ND TRANSITION SHOWN IN VERTICAL DISCHARGE APPLICATION WITH IN LINE OR REMOTE BLOWER REFER TO INSTALLATION INSTRUCTIONS FOR HORIZONTAL DISHCARGE Install Ductwork LOW PROFILE WALL HOODS 24 610 OR 27 686 DEPTH OF HOOD NOTE HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT 18 457 HEIGHT OF HOOD DUCTWORK INSTALLATION THROUGH ROOF 30 762 TO 36 914 COUNTERTOP TO BOTTOM OF HOOD 24 AND 27 DEEP WALL HOODS ...

Page 12: ...ustration below Remove the center filter first Gloves should be worn when handling filters If you are using an in line or remote blower attach the optional 10 254 round transition or custom piece to the top of the wall hood using holes provided If you are installing an in line or remote blower drill a 7 8 22 hole through the wood framing for the conduit Refer to the illustration below for location...

Page 13: ...ts in preparation for attaching the hood to wall framing Position the hood in the desired location on the wall Depending on the application install the 10 x 11 2 38 screws with washers or 3 76 drywall screws through the mounting holes on the back plate Verify that the screws engage the wall framing If not wall anchors must be used If additional support is required for the wall hood drill supplemen...

Page 14: ...e the brackets in place The brackets should be mounted 1 2 13 above the top of the wood mounting support For ease of installation the location of the wood mounting support and retaining bracket allow for 1 2 13 clearance at the top of the hood This gap will be taken up during final mounting of the hood to the mounting support Refer to the illustration below for the location of mounting holes for p...

Page 15: ...ctions provided with the blower assembly Install the internal blower to the back plate assembly prior to mounting the hood If a duct cover is to be used follow the instructions on page 9 before installing the hood If you are installing a recirculating kit refer to instructions included with the kit before installing the hood The hood is shipped with the back plate and transition assembly attached ...

Page 16: ... If a backsplash is to be used it should be installed prior to mounting the wall hood Refer to installation instructions provided with the backsplash Align the mounting holes in the back plate of the hood assembly with the retaining brackets on the wood mounting support Refer to the illustration below for location of the mounting holes one on each side of the back plate Position the hood and insta...

Page 17: ...pply white wire and green wire to green wire or bare wire Place all wiring connections inside the electrical box and reinstall on the back plate in the upper right hand corner Make sure that the wires are secure and that no wires are pinched between the cover and box ELECTRICAL BOX Location of electrical box FILTER INSTALLATION Slide the grease cups along the bottom edge of the hood so that the li...

Page 18: ...n hoods are shipped without the blower assembly Internal in line and remote blowers are avail able through your authorized Wolf dealer For local dealer information visit the find a showroom section of our website wolfappliance com The blower will vary in size and is dictated by the cooking surface the volume of air that needs to be moved and the length of the duct run Refer to ventilation recommen...

Page 19: ...ll hoods Once the hood installation is complete plug the blower power cord s into receptacle s located near the center of the hood shell Refer to the illustration below Use the clips on the interior of the hood to secure excess power cord IMPORTANT NOTE Before turning the power on to the ventilation hood make sure the blower is off Internal Blowers IMPORTANT NOTE For low profile wall hoods using t...

Page 20: ...ll studs or roof rafters Avoid pipes wires and other ductwork Be sure there is enough space for transitions needed between the blower and connecting ductwork For best performance locate transitions nearest the blower 241 2 622 151 2 394 281 4 718 203 4 527 243 4 629 14 356 43 4 121 10 254 Diameter 143 4 375 291 2 749 291 2 749 18 457 22 559 101 8 257 71 4 184 10 254 10 254 Diameter 143 4 375 291 2...

Page 21: ...ocate the cord assembly provided with the blower The cord assembly has two leads black L1 and white neutral Connect these leads to the leads from the blower black to black and white to white Connect all green and bare wires together to the ground screw in the electrical box Plug the cord assembly into the receptacle located near the center of the hood shell Refer to the illustra tion below Use the...

Page 22: ...air the ventilation hood yourself Wolf is not responsible for service required to correct a faulty installation Service Information If service is necessary maintain the quality built into your ventilation hood by calling a Wolf authorized service center To obtain the name and number of a Wolf authorized service center check the contact support section of our website wolfappliance com or call Wolf ...

Page 23: ... copyright property of Wolf Appliance Inc Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance Inc Wolf Appliance Inc all rights reserved ...

Page 24: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 332 9513 811504 REV B 4 2010 ...

Reviews: