background image

wolfappliance.com/specs

Pro Hood Liner Specifications

5

Overall Dimensions

PRO HOOD LINERS

Installation

PRO HOOD LINERS

WIDTH MINUS

6"

(152)

12"

(305)

4"

(102)

19

1

/

4

"

(489)

22

1

/

2

"

(572)

DEPTHS

12"

(305) 

3"

(76)

3"

(76)

34

3

/

8

"

(873)

, 40

3

/

8

"

(1026)

, 46

3

/

8

"

(1178)

52

3

/

8

"

(1330)

, 58

3

/

8

"

(1483) WIDTHS

LINER WIDTH

DECORATIVE HOOD

FOR

19

1

/

4

"

31"

(787) TO

36"

(914) 

FOR 

22

1

/

2

"

30"

(762) TO

36"

(914) 

12"

(305)

 LINER HEIGHT

19

1

/

4

"

(489)

LINER DEPTH

22

1

/

2

"

(572)

LINER DEPTH

SIDE VIEW

ELECTRICAL

LOCATION

HOOD LINER

E

7

5

/

8

"

(194)

12

1

/

2

"

(318)

Summary of Contents for Pro Ventilation Hood Liners

Page 1: ...INSTALLATION GUIDE Pro Ventilation Hood Liners ...

Page 2: ...tions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Pro Hood Liners 3 Installation Considerations 4 Pro Hood Liner Specifications 5 Pro Hood Liner Installation 7 Service Information 11 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date info...

Page 3: ...National Electrical Codes as well as all state municipal and local codes The correct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product rating plate Record the model and serial numbers before installin...

Page 4: ...information visit the find a showroom section of our website wolfappliance com Blower size is dependant on the size of the cooking surface volume of air being moved and length of the duct run Refer to ventilation recommendations in the Wolf design guide In line and remote blowers require a Romex not provided from the blower to the ventilation hood For blower installation refer to specific instruct...

Page 5: ... 6 152 12 305 4 102 191 4 489 221 2 572 DEPTHS 12 305 3 76 3 76 343 8 873 403 8 1026 463 8 1178 523 8 1330 583 8 1483 WIDTHS LINER WIDTH DECORATIVE HOOD FOR 191 4 31 787 TO 36 914 FOR 221 2 30 762 TO 36 914 12 305 LINER HEIGHT 191 4 489 LINER DEPTH 221 2 572 LINER DEPTH SIDE VIEW ELECTRICAL LOCATION HOOD LINER E 75 8 194 121 2 318 ...

Page 6: ...ce should have its own 15 amp circuit breaker Locate the electrical supply within the shaded area shown in the installation illustration on the previous page In line and remote blowers require a Romex not provided from the blower to the ventilation hood IMPORTANT NOTE You must follow all National Electrical Code regulations In addition be aware of local codes and ordinances when installing your se...

Page 7: ...hood liner Use sheet metal screws and aluminum tape or high temperature duct tape to seal joints between ductwork sections All pro hood liners include a backdraft damper in the tran sition assembly Local codes may require the use of an additional backdraft and or make up air damper Contact your local HVAC professional for specific requirements Backdraft and make up air dampers are available throug...

Page 8: ... significantly decrease performance 1 To remove filters press upward then rotate bottom outward Refer to the illustration below To aide in removal remove center filter first Gloves should be worn when handling filters 2 The damper is packaged inside the hood liner in a separate box Remove damper from box and place it on top of the hood liner using the hold down brackets 3 Secure hold down brackets...

Page 9: ...he electrical box cover from inside the hood liner Insert Romex from service panel and Romex from in line or remote blower if applicable through the back of the hood liner and into the electrical box Secure with an appropriate electrical connector Refer to the illustration below 2 Use wire connectors provided to connect black to black white to white and green to green bare wire For in line and rem...

Page 10: ...LTER INSTALLATION To install filters press upward then rotate bottom outward The filter vanes should be placed perpendicular to the front of the hood Refer to the illustration below To aide in removal remove center filter first Gloves should be worn when handling filters LIGHT BULB INSTALLATION A suction cup style light bulb changer is provided with pro hood liners Use the changer to push the bulb...

Page 11: ...ir respective owners in the United States and other countries Service Information If service is necessary maintain the quality built into your pro hood liner by contacting Wolf factory certified service For the name and number of Wolf factory certified service nearest you check the contact support section of our website wolfappliance com or call Wolf customer care at 800 222 7820 When calling for ...

Page 12: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 222 7820 821558 REV B 8 2012 ...

Reviews: