Wolf PI543418 Use & Care Manual Download Page 4

Safety Instructions

4

IMPORTANT INSTRUCTIONS

IMPORTANT NOTE:

Read all safety instructions before

using this appliance.

Read this use & care guide carefully before using
your new ventilation hood to reduce the risk of fire,
electric shock or injury to persons.

Ensure proper installation and servicing. This
appliance must be properly installed and grounded
by a qualified technician.

Warranty service must be performed by Wolf factory
certified service.

Installation work and electrical wiring must be done
by qualified person(s) in accordance with all applica-
ble codes and standards, including fire-rated
construction codes and standards.

Use the ventilation hood only in the manner intended
by Wolf Appliance, Inc. If you have questions,
contact us at 800-222-7820.

Before servicing or cleaning, switch power off at the
service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
can not be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.

Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent back drafting.

Follow the heating equipment manufacturer’s guide-
line and safety standards such as those published
by the National Fire Protection Association (NFPA),
the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE) and the local
code authorities.

GENERAL SAFETY REQUIREMENTS

For general ventilating use only. Do not use this
ventilation hood to exhaust hazardous or explosive
materials and vapors.

Ducted fans must always be vented to the outdoors.

To reduce the risk of fire, use only metal ductwork.

To reduce the risk of electric shock, this hood should
only be used with fan speed control CM-18RT1 and
CM-18RSTU2. Do not use this hood with an addi-
tional speed control device.

For best capture of cooking impurities, the bottom of
the hood should be a minimum of 30" (762) and a
maximum of 36" (914) above the countertop.

To avoid motor bearing damage and noisy or unbal-
anced impellers, keep drywall spray, construction
dust, etc. off power unit.

When cutting or drilling into wall or ceiling, do not
damage electrical wiring or other hidden utilities.

Please read the specification label on the ventilation
hood for further information and requirements.

To reduce the risk of fire and to properly exhaust
air, always duct air outside. Do not vent exhaust air
into spaces within walls or ceilings or into attics,
crawl spaces or garages.

Summary of Contents for PI543418

Page 1: ...USE CARE GUIDE Pro Ventilation Hoods...

Page 2: ...NG states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Pro Ventilation Hoods 3 Safety Instructions 4 Pro Ventilation Hood Features 6 Pro Ventilation Ho...

Page 3: ...portance and have designed and built your ventilation hood with quality materials and workmanship to give you years of dependable service Before you begin using your ventilation hood please take some...

Page 4: ...pment to prevent back drafting Follow the heating equipment manufacturer s guide line and safety standards such as those published by the National Fire Protection Association NFPA the American Society...

Page 5: ...pliance unless specifically recommended in this guide All other service should be performed by a qualified technician The hood motor has a thermal overload that will automatically shut off the motor i...

Page 6: ...and five year residential warranty PRO LOW PROFILE WALL HOOD Model PW482210 shown Removable baffle filters Halogen lighting Welded seams and hemmed edges Heavy duty stainless steel Recessed easy acces...

Page 7: ...y kit UL listed to US and Canadian safety standards Two and five year residential warranty PRO 27 686 DEEP WALL HOOD Model PW482718 shown Removable baffle filters Halogen lighting Welded seams and hem...

Page 8: ...raft damper UL listed to US and Canadian safety standards Two and five year residential warranty PRO ISLAND HOOD Model PI543418 shown Removable baffle filters Halogen lighting Seamed construction Heav...

Page 9: ...ain local dealer information visit the locator section of our website wolfappliance com Internal in line and remote blowers 38 high stainless steel backsplash with or without warming racks for wall ho...

Page 10: ...mp or to the left to activate the left lamp When the knob is in the vertical position both heat lamps will be activated BLOWER CONTROL The right control knob which operates the blower is variable allo...

Page 11: ...the blower and lights and allow the halogen bulb to cool before replacing To remove apply the suction cup to the light bulb push the bulb into the receptacle and rotate counter clockwise one quarter t...

Page 12: ...pened microfiber cloth followed by a dry polishing chamois All work should follow the grain direction of the finish Better results are obtained by keeping the cloth in continuous contact with the stai...

Page 13: ...ends wiping filters and grease cups to remove any excess grease before placing in the dishwasher Refer to filter removal on the previous page Troubleshooting If your Wolf ventilation hood is not opera...

Page 14: ...e model and serial numbers of your unit are printed on the enclosed Wolf product registration card If you provide us with your e mail address we will send you exciting new product updates and recipes...

Page 15: ...MS APPLICABLE TO EACH WARRANTY The warranty applies only to products installed for normal residential use The warranty applies only to products installed in any one of the fifty states of the United S...

Page 16: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 222 7820 816995 REV A 10 2010...