6
1
Thermal insulation:
Position (overlapping) around the boiler block and secure with spring clips.
2
Spacers:
Secure on the boiler with nuts enclosed.
(MKS-85 to 500)
Four
spacers at the real panel.
(MKS-85 to 140)
Two
bottom spacers per side.
(MKS-190 to 500)
Three
bottom spacers per side and
one
central top spacer.
3
Thermal insulation:
Loosely fitted to the rear boiler wall.
4
Rear panels:
Centrally locate both parts and secure with self-tapping screws and with the screws (M8x16)
supplied on the rear boiler wall spacers.
5
Thermal insulation:
Insert from the top between door and boiler front and locate on the boiler front.
6
Thermal insulation:
Fit loosely to the boiler front and secure with spring clips.
7
Thermal insulation:
Fit loosely to the boiler front and secure with adhesive strips.
8
Side panels:
Push the l.h./r.h. casing over the rear panel and secure with the screws
(MUS-85 to 100 / MKS-85 to 140)
(M8x16) supplied to the lower
two
spacers.
8
Side panels:
Secure the l.h./r.h. front and rear panels with screws (M6x10) then push over the rear panel
(MKS-190 to 500)
and secure with the screws (M8x16) supplied on the lower
three
spacers.
9
Wolf label:
Hook into the front panel lid (10).
10 Front panel lid:
Locate and click into the panel with fitted control unit.
Only complete the fitting of the casing after the control unit has been installed (page 7).
10 Panel lid l.h. rear:
Locate on the panel and click into place.
10 Panel lid r.h. rear:
Locate on the panel and click into place.
13 Type plate:
Affix to the boiler in a clearly visible position.
Accompanying documentation:
Affix with the clips supplied to the side of the boiler.
Casing installation
Burner cables
1
st
stage
2
nd
stage
Boiler sensor
Control unit cable