background image

 
 
 

 

 

 

Top and bottom seals are 
fastened with three 
screws to bracket. 

Side seal is glued in 
with special stove 
cement. 

 

7.7 

Heating during Transition Periods 

During transition periods (Spring / Fall), outside temperatures of over 16°C can cause a smoke buildup in the woodstove. If 
sufficient draft cannot be created with a startup fire at this temperature (= rapid generation of high heat by quick burning of 
newspaper), so that the fumes are not completely removed, then you should abandon your plans for a fire. Use newspaper 
as fuel for a startup fire. Add less wood during transition periods or wait longer before adding more wood.  
The fireplace should be filled with less fuel (wood) and operated at a higher setting of the primary draft control lever so that 
the existing fuel burns faster (in flames), which will stabilize the chimney draft. In addition, the wait time between adding 
wood for reheating should be extended. To avoid resistance in the firebed, ashes should be carefully scraped off on a regu-
lar basis. 
 

8.

 

Cleaning and Maintenance 

Very important: All cleaning and maintenance work must only be performed on a completely 
cooled down fireplace!!! 

8.1 

Door Gasket Seal 

The door is equipped with a special ceramic seal. This prevents an unwanted vacuum 
exhaust of combustion air. The woodstove can then be regulated with the primary 
and secondary draft control levers. 

 
 
 
 

 
 

 

 

8.2 

Cleaning the Woodstove  

Fireplace stoves are designed so that the secondary air draft also serves as a “rinsing air” for the glass window. With proper 
installation and correct positioning of the chimney, the glass will remain generally clean on its own. Despite this fact, a 
buildup of a fine layer of soot dust is often unavoidable, and this is magnified by poor fuel (wet wood) and/or constant draft 
with limited efficiency. 

 
Important: Only clean the glass after the woodstove has completely cooled!!! 
Warning: Do not use abrasive cleaners!!! 

 
Only clean the glass after the woodstove has completely cooled. Use some moist paper that has been dipped in the cool 
ashes to remove the soot on the glass window. As a final step in the cleaning process, use some fresh paper with clean wa-
ter to rinse the window. Even if the chimney is not cleaned every year, the joints between the oven and the chimney should 
be cleaned every year. In general, you should keep the fireplace and flue clean at all times. 
Small cracks in the baffle bricks, due to heat stress, are unavoidable and will not have an adverse effect on its function or 
durability under normal operating conditions. Consult your dealer if you notice more extensive damage.  
Check the door gasket seal on a regular basis for damage and replace, if necessary.  
Keep the fireplace and flue clean. If you are a frequent user of your woodstove, you should also have the chimney cleaned 
on a regular basis.  
If a fire should occur in the chimney or a real risk of fire exists, immediately close the draft intake lever and the door. If 
necessary, call the fire department to extinguish the fire. Always call the local authorities after a chimney fire so that the 
chimney can be inspected. If a gray haze should appear on the outer surface after an overheating situation, this can be re-
moved and/or touched up with specialty spray paint for woodstoves. 

Summary of Contents for Lascar

Page 1: ...tenance Manual for Stromboli Lascar Manufactured by Imported by Frohnhof 9 PO Box 120 91580 Petersaurach Pound Ridge NY Germany T 49 9802 951473 T 914 764 5679 F 49 9802 9589909 F 614 764 0465 www wolf bavaria com www wittus com ...

Page 2: ...Installation Operator Maintenance Manual STROMBOLI Model 0700 Steel Model 0701 Soap Stone Model 0702 Tiles LASCAR Model 0601 Soap Stone Model 0602 Tiles ...

Page 3: ...l kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater Keep all such liquids well away from heater while it is in use 10 DO NOT OVERFIRE If heater or chimney connector glows you are overfiring Overfiring this appliance could cause a house fire Overfiring is a condition where the appliance is operated at temperatures above its design capa bilities Overfiri...

Page 4: ...cern for aesthetics efficiency and our environment We extend our continued support to help you achieve the maximum benefit and enjoyment available from your new German wood stove It is our goal at Wolf Bavaria to provide you our valued customer with an appliance that will ensure you years of trouble free warmth and pleasure Thank you for selecting a Wolf Bavaria Products stove as the answer to you...

Page 5: ...8 Combustible Wall Chimney Connector Pass Throughs 15 3 User s Guide 16 3 1 Hand Protection 16 3 2 Technical Data and Dimensions 16 3 3 Delivery 17 3 4 Unpacking 18 3 5 Acceptable Fuel 18 4 Safety Please read very important 18 5 Fresh Air Supply 19 6 Operating Your Woodstove 19 6 1 Regulating the Heat 19 6 2 Door 20 6 3 Ash Drawer 20 7 Heating Operation 20 7 1 First Use 20 7 2 Starting a Fire 21 7...

Page 6: ...82 Canadian Test Standard CAN ULC S627 EPA Exemption Certification Packaging List One Installation and operation instruction manual One Warranty One Set of Baffle Bricks One Set of Tiles or Soap Stone One Glove One Lever for the Secendary Air Using this Manual Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provi...

Page 7: ...herefore a central location is often best There are other practical considerations which must be considered before a final selection of location is made Existing Chimneys Wood Storage Aesthetic Considerations Roof Design Rafter Locations Roof Pitch Room Traffic Proximity to Combustibles Electrical Wiring The installation of this stove will require some research Once your options are determined con...

Page 8: ...460 E 18 460 B 12 305 D 11 280 Clearances Canada inches millimeters A 21 535 C 27 685 E 27 685 B 21 535 D 20 510 The minimum clearance from the stove front is 52 inch 1320mm for both Canada and US This dinension must be used by a rotable 360 Stove PROTECTED WALL CLEARANCE when the stove is installed adjacent to a protected wall system the variance must be approved by your local building official N...

Page 9: ...r protector must be installed with an R value of 1 0 English units Use of a listed floor protector is acceptable An easy means of determining if a proposed alternate floor protector meets these requirements is to follow this proce dure 1 Convert specification to R value i R value is given no conversion is needed ii k factor is given with a required thickness T in inches R 1 k x T iii C factor is g...

Page 10: ... of the above symptoms 4 The house is equipped with a well sealed vapor barrier and tight fitting windows and or has any powered devices that exhaust house air 5 There is excessive condensation on windows in the winter 6 A ventilation system is installed in the house b If these or other indications suggest that infiltration air is inadequate additional combustion air should be provided from the ou...

Page 11: ...fuel door Install the marble gasket and marble as follows 1 Install gasket on stove top as shown in the illustration The ceramic fiber blanket and strips cerawool which come with each unit must be placed under the marble to insulate it from high temperatures on top of the firebox Do not place the marble directly on the top metal surface of the stove or it will crack 2 Place top marble piece onto t...

Page 12: ...iece usually called a dripless connector to join single wall pipe to their factory built chimney section Minimum Flue Size The required minimum diameter and area required for the flue size is respectively 6 152 mm diameter which is approximately 28 square inches 711 square mm The maximum flue size should be no more than three times the cross sectional area of the size of the 6 152 mm diameter flue...

Page 13: ...ny additional re quirements for your area Due to prevailing winds local terrain adjacent tall trees a hill or ravine near the home or adjacent structures additional chimney height or a special chimney cap may be required to ensure optimum performance To achieve a stable draft the total flue height required from the appliance to termination is 12 to 15 feet 366 to 457 cm minimum 2 7 Draft Requireme...

Page 14: ......

Page 15: ...l thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 mm separation area containing fiber glass insula tion from the wall thimble and cover its opening with a 24 gage minimum sheet metal support Maintain the 6 152 mm space There should also be a support sized to fit and hold the metal chimney connector See that the support is fastened s...

Page 16: ...3 User s Guide 3 1 Hand Protection Please use protective gloves when opening the doors You can then add wood while the handle is hot 3 2 Technical Data and Dimensions LASCAR STROMBOLI ...

Page 17: ...alculated as follows according to DIN 18 893 for rooms that do not have insulation that complies with the Heat Insulation Ordinance For favorable heating conditions calculated according to DIN 4701 At less favorable heating conditions 145 m At unfavorable heating conditions 98 m For interval heating with interruptions of more than 8 hours the heating capacity is reduced by 25 3 3 Delivery Damage c...

Page 18: ... first time This will provide you with information about how to safely operate your stove During operation the woodstove s surface will become very hot Pay attention in particular to children playing in the vicinity of the stove as they are most likely to be at risk of injury Keep small children away from the stove Make sure that no combustible material is located in the vicinity of or on top of t...

Page 19: ...n The location that is used to support the base of the woodstove must be horizontal and without any uneven spots 6 Operating Your Woodstove 6 1 Regulating the Heat A control to regulate the secondary air is located above the door in the mid dle Open the faceplate under the fireplace door Reach into the recess and pull 1 Secondary Draft Control The secondary draft control lever regulates the amount...

Page 20: ...oodstove should not be used until after you have obtained approval from the proper authorities regarding its proper installation and conditions of use The woodstove is designed to burn only wood i e pieces of wood or wood briquettes The wood must be dry moisture 20 and untreated The burning of any other materials such as chipboard painted laminated impregnated or synthetic coated wood garbage etc ...

Page 21: ...ature As a result the wood does not burn up cleanly and soot is built up on the glass and the fireclay walls Therefore fill your woodstove about halfway with wood pieces and replenish on a regular basis Your woodstove is not a garbage burning incinerator Use only wood or wood briquettes for fuel 7 4 Adding Wood Do not add wood until the flames have stopped blazing First open the draft controls com...

Page 22: ...lation and correct positioning of the chimney the glass will remain generally clean on its own Despite this fact a buildup of a fine layer of soot dust is often unavoidable and this is magnified by poor fuel wet wood and or constant draft with limited efficiency Important Only clean the glass after the woodstove has completely cooled Warning Do not use abrasive cleaners Only clean the glass after ...

Page 23: ...le it is in operation The heating process causes the top surface of the woodstove as well as its operating elements including the window and flue to become extremely hot Do not touch any of these parts without appropriate protective gear or tools e g heat protection gloves Never put laundry or other objects on the stove to dry Objects that are not heat resistant should never be placed on top of th...

Page 24: ... 1 Replacement Tiles 13 2 Replacement Glas and Door Handle IMPORTANT Replace glass only with glass from the manufacturer or distributor of this appliance Glass Dimensions Hight 550 0mm Width 420 0mm Thickness 4 0mm Radius 420 0mm ...

Page 25: ...r of this appliance We sincerely hope that your Wolf Bavaria woodstove provides you with many cozy hours of warmth and enjoyment Manufactured by Imported by Frohnhof 9 PO Box 120 91580 Petersaurach Pound Ridge NY Germany USA T 49 9802 951473 T 914 764 5679 F 49 9802 9589909 F 614 764 0465 www wolf bavaria com www wittus com ...

Reviews: