INSTALLATION REQUIREMENTS:
1.  A  gas  pressure  regulator  sized  for  this  unit  is  included.  

Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.

2.  Gas line connecting to appliance must be ¾" diameter or 

larger. If flexible connectors are used, the inside diameter 
must be the same as the ¾" iron pipe.

3.  An  adequate  ventilation  system  is  required  for  commer-

cial  cooking  equipment.  Information  may  be  obtained  
by  writing  to  the  National  Fire  Protection Association,  
1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org. 
When writing, refer to NFPA No. 96.

4.  These units are manufactured for installation in accordance 

with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American 
Gas  Association,  Accredited  Standards  Committee  Z223 

 

Model 

 

 

 

Grid Rack 

Total 

Approx. Shp.

 

No. 

Width 

Depth 

Height 

(w x d) 

BTU/hr. 

Wt. (lbs./kg)

 

IRB36 

36" 

19" 

17½" 

27½" x 13" 

30,000 

180/81

@  400N.  Capital  St.  NW,  Washington,  DC  20001,  or  the 
Secretary Standards Council, NFPA, 1 Batterymarch Park, 
Quincy, MA 02169-7471.

 

 

NOTE: In the Commonwealth of Massachusetts

 

All  gas  appliances  vented  through  a  ventilation  hood  or 
exhaust system equipped with a damper or with a power 
means of exhaust shall comply with 248 CMR. 

5.  Clearances:
 

 

Combustible 

Non-Combustible

 

Rear 

0" 

0"

 

Sides 

2" 

0"

 

Bottom 

10" 

4"