background image

10

W O L F  

G A S   C O O K TO P S

IMPORTANT NOTE:

The gas cooktop must be

connected to a regulated gas supply. 

IMPORTANT NOTE:

This installation must

conform with local codes and ordinances. 

IMPORTANT NOTE:

The natural gas cooktop

is rated for elevations up to 2438 m without
adjustment. Install a high altitude kit for eleva-
tions from 2438 to 3084 m. The LP gas cooktop
is rated for 3084 m.

The rating plate, located on the underside of
the burner box, has information on the type of
gas that should be used. If this information
does not agree with the type of gas available,
check with the local gas supplier.

EXPLOSION HAZARD —

Securely tighten all external gas 
connections.

Failure to do so can result in explosion,
fire or death.

G A S S U P P LY  

R E Q U I R E M E N T S

Provide a gas supply line of 19 mm rigid pipe
to the cooktop location. A smaller size pipe on
long runs may result in insufficient gas supply.
Pipe joint compounds, suitable for use with LP
gas should be used. For LP gas, piping or
tubing size can be 13 mm minimum. LP gas
suppliers usually determine the size and mate-
rials used on the system.

If local codes permit, a flexible metal appliance
connector is recommended for connecting this
cooktop to the gas supply line. Do not kink or
damage the flexible connector when moving
the cooktop. You will need to determine the
fittings required, depending on the size of your
gas supply line, flexible metal connector and
shut-off valve.

If rigid pipe is used as a gas supply line, a
combination of pipe fittings must be used to
obtain an in-line connection to the cooktop. All
strains must be removed from the supply and
gas lines so the cooktop will be level and in
line.

I M P O R T A N T
N O T E

This installation
must conform with
local codes and
ordinances. 

G A S

R A T I N G

Total Heat 

Electrical 

Types and 

Output Gas  Rating Appliance 

Pressures 

Model # 

(Gas)

Units

(Watts) 

Category 

(mbar)

Country of Destination 

I2H

G20 at 20

AT, DK, EE, FI, GR, IE, IT, LT, 

ICBCT15G/S

6.8

kW

230

NO, PT, ES, SE, SI, SK, GB, CH

I2E

G20 at 20

DE, PL

I2E+

G20 at 20/25

BE, FR

ICBCT15G/S-LP

494

g/h

230

I3P

G31 at 37

BE, CZ, FR, GR, IE, NL, NO, PT, 
ES, GB, CH

I2H

G20 at 20

AT, DK, EE, FI, GR, IE, IT, LT, 

ICBCT30G/S

14.7

kW

230

NO, PT, ES, SE, SI, SK, GB, CH

I2E

G20 at 20

DE, PL

I2E+

G20 at 20/25

BE, FR

ICBCT30G/S-LP 1069

g/h

230

I3P

G31 at 37

BE, CZ, FR, GR, IE, NL, NO, PT, 
ES, GB, CH

I2H

G20 at 20

AT, DK, EE, FI, GR, IE, IT, LT, 

ICBCT36G/S

17.7

kW

230

NO, PT, ES, SE, SI, SK, GB, CH

I2E

G20 at 20

DE, PL

I2E+

G20 at 20/25

BE, FR

ICBCT36G/S-LP 1287

g/h

230

I3P

G31 at 37

BE, CZ, FR, GR, IE, NL, NO, PT, 
ES, GB, CH

Summary of Contents for Gas cooktop

Page 1: ...GAS COOKTOPS INSTALLATION INSTRUCTIONS INSTRUCCIONES DE INSTALACIÓN INSTRUCTIONS D INSTALLATION ISTRUZIONI PER L INSTALLAZIONE ...

Page 2: ... Another footnote we would like to identify is IMPORTANT NOTE This highlights informa tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if you do not follow instructions states a hazard that may cause serious injury or death if precautions are not followed WOLF is a registered trademark of Wolf Appliance Inc C O N TA ...

Page 3: ...apors and liquids in the vicinity of this or any other appliance The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed Ensure that the kitchen is well ventilated keep natural ventila tion holes open or install a mechani cal ventilation device mechanical extractor hood Prolonged intensive use of the appli ance may for additional venti...

Page 4: ...re listed on the product rating plate Record the model and serial numbers before installing the cooktop Both numbers are listed on the rating plate located on the underside of the cooktop Refer to the illustration below 4 BEFORE YO U S TA RT Proper installation is your responsibility Have a qualified technician install this cooktop You must also assure that electri cal installation is adequate and...

Page 5: ...op will be installed The location should be away from strong draft areas such as windows doors and strong heating vents or fans Do not obstruct flow of combustion and ventilation air This appliance is not connected to a combustion products evacuation device It shall be installed and connected in accor dance with current installation regulations Particular attention shall be given to the relevant r...

Page 6: ...of cooktop cut out to combustible materials up to 457 mm above countertop Minimum clearance from rear edge of cooktop cut out to combustible materials up to 457 mm above countertop 489 mm COOKTOP CUT OUT DEPTH 64 mm min 914 mm STANDARD FLOOR TO COUNTERTOP HEIGHT 330 mm max 762 mm COUNTERTOP TO COMBUSTIBLE MATERIALS ABOVE COOKTOP 64 mm 127 mm LOCATION OF GAS SUPPLY MAY ALSO EXTEND 127 mm ON FLOOR F...

Page 7: ...cifications for Model ICBCT30G IMPORTANT NOTE 838 mm wide cabinets are recommended for installation of Model ICBCT30G A Wolf 762 mm single built in oven may be installed below Model ICBCT30G For this installation unless you are using cabinets deeper than 610 mm it is recommended that the electrical and gas supply be placed in the base cabinet to the right of the oven Refer to installation instruct...

Page 8: ...ple cooktop units are installed side by side refer to the countertop cut out dimensions on page 9 229 mm min CUT OUT TO COMBUSTIBLE MATERIALS BOTH SIDES 457 mm 489 mm COOKTOP CUT OUT DEPTH 914 mm STANDARD FLOOR TO COUNTERTOP HEIGHT 330 mm max 762 mm COUNTERTOP TO COMBUSTIBLE MATERIALS ABOVE COOKTOP 610 mm min Minimum clearance from both side edges of cooktop cut out to combustible materials up to ...

Page 9: ...ts own separate recommended electrical circuit When two or more modules are installed together an integrated module filler strip IFILLER S is recommended Contact your Wolf dealer for information on these accessory components 64 mm min FRONT OF COUNTERTOP 489 mm CUT OUT DEPTH 743 mm TWO MODULES WIDTH 1130 mm THREE MODULES WIDTH OR 1124 mm 762 mm COOKTOP AND ONE MODULE 1518 mm FOUR MODULES WIDTH OR ...

Page 10: ... is recommended for connecting this cooktop to the gas supply line Do not kink or damage the flexible connector when moving the cooktop You will need to determine the fittings required depending on the size of your gas supply line flexible metal connector and shut off valve If rigid pipe is used as a gas supply line a combination of pipe fittings must be used to obtain an in line connection to the...

Page 11: ...peration W I R I N G D I A G R A M A wiring diagram covering the control circuit for each Wolf gas cooktop model can be found on page 15 IMPORTANT NOTE If codes permit and a separate ground wire is used it is recom mended that a qualified electrician determine that the ground path is adequate IMPORTANT NOTE Check with a qualified electrician if you are not sure whether the cooktop is properly grou...

Page 12: ... Reinsert the cooktop into the countertop opening Check that the cooktop is parallel to the front edge of the countertop Lift the entire cooktop to make adjustments and align the rear edge with the pencil line Attach the brackets to the burner box Insert the 89 mm clamping screws into the brackets Use a screwdriver to tighten the clamping screws against the underside of the counter top Refer to th...

Page 13: ...wn Check operation again if the burners do not light properly at this point contact a Wolf authorized service center IMPORTANT NOTE Initial lighting of the surface burners may take slightly longer as air in the system must be purged before gas can be supplied to the burner COOKTOP R E M O VA L If it is necessary to remove the cooktop for cleaning or service shut off the gas supply Disconnect the g...

Page 14: ... model and serial numbers Both numbers are listed on the rating plate located on the underside of the cooktop Refer to the illustration on page 4 for location of the rating plate The information and images in this book are the copyright property of Wolf Appliance Inc an affiliate of Sub Zero Inc Neither this book nor any information or images contained herein may be copied or used in whole or in p...

Page 15: ...del ICBCT15G POWER CORD WHITE RIGHT FRONT BLACK RIV GAS VALVE RED RED RED RED WHITE GRN YEL BLACK RIGHT REAR LEFT REAR LEFT FRONT BLACK WHITE WHITE BLACK LEFT FRONT POWER CORD RED RIV GAS VALVE WHITE BLACK RIGHT REAR LEFT REAR RIGHT FRONT CTR REAR GRN YEL BLACK RED RED RED BLACK WHITE WIRING D I A G R A M S Model ICBCT30G Model ICBCT36G ...

Page 16: ...WOLF APPLIANCE INC PO BOX 44848 MADISON WI 53744 USA WOLFAPPLIANCE COM 8 1 0 1 2 7 1 1 2 0 0 7 ...

Reviews: