LOCATION

CAUTION: The equipment area must be kept free and clear of combustible substances.

Installation clearances:

COMBUSTIBLE

NONCOMBUSTIBLE

CONSTRUCTION

CONSTRUCTION

Back:

6"

0"

Right Side:

6"

0"

Left Side:

6"

0"

The installation location must allow adequate clearances for servicing and proper operation.  A
minimum front clearance of 35" (88 cm) is required.

There must be at least 16" (406.4 mm) clearance between the fryer and any open top flame units.
Adequate clearances for servicing and proper operation must be allowed.

Install the fryer in an area with sufficient air supply for combustion of the gas at the fryer burners.
Provide adequate clearance for air openings into the combustion chamber.  Do not obstruct the flow
of combustion and ventilation air.

Do not permit fans to blow directly at the fryer.  Wherever possible, avoid open windows next to the
sides or back of the fryer.  Avoid wall-type fans which create air cross currents within the room.

INSTALLATION CODES AND STANDARDS

Your Wolf Fryer must be installed in accordance with:

In the United States of America:

1. State and local codes.

2. National Fuel Gas Code, ANSI-Z223.1 (latest edition).  Copies may be obtained from The

American Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.

3. ANSI-NFPA Standard #96, Vapor Removal from Cooking Equipment, (latest edition), available

from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1. Local codes.

2. CSA B149.1 Natural Gas and Propane Installation Code.

3. CSA C22.2  Canadian Electrical Code.

The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,
Mississauga, Ontario, Canada L4W 5N6.

Summary of Contents for FWTF-42

Page 1: ...E DIVISION OF ITW FOOD EQUIPMENT GROUP LLC WWW WOLFRANGE COM 2405 MIRA MAR AVENUE LONG BEACH CA 90815 TEL 562 597 0811 INSTALLATION OPERATION MANUAL For additional information on Wolf Range or to locate an authorized parts and service provider in your area visit our website at www wolfrange com ...

Page 2: ...vious experience with the operation of the equipment covered in this manual QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals a firm corporation or company which either in person or through a representative are engaged in and are responsible for 1 The installation of gas piping from the outlet side of the gas meter or the service regulator when the meter is not prov...

Page 3: ...s with the specifications on the fryer data plate which is located on the inside of the door Also be sure the fryer is built for the installation elevation The fryer must be restrained with adequate ties to prevent tipping when installed in order to avoid the splashing of hot liquid UNPACKING This fryer was carefully inspected before leaving the factory The transportation company assumes full resp...

Page 4: ...bustion and ventilation air Do not permit fans to blow directly at the fryer Wherever possible avoid open windows next to the sides or back of the fryer Avoid wall type fans which create air cross currents within the room INSTALLATION CODES AND STANDARDS Your Wolf Fryer must be installed in accordance with In the United States of America 1 State and local codes 2 National Fuel Gas Code ANSI Z223 1...

Page 5: ...piping to limit the appliance movement Attach the restraining device to the rear of the fryer as shown in Fig 1 If it is necessary to disconnect the restraint turn off the gas supply before disconnection Reconnect the restraint before turning the gas supply on and returning the fryer to its installation position Instructions for installing casters to the fryer are included with the casters LEVELIN...

Page 6: ...r must have a maximum regulation capacity to handle the total connected load and must have an adjustment range for manifold pressure marked on the equipment rating plate s If the manifold pressure of the connected equipment is not the same a separate regulator must be supplied for all devices operating under different manifold pressure ratings CONNECTION OF MANIFOLDS IN BATTERY 1 If the fryer requ...

Page 7: ...nd with local codes Never make flue connections directly to the fryer The fryer must be located under a hood which has an adequate connection to an exhaust duct The hood must extend 6 152 4 mm beyond fryer sides Clearance above fryer should be adequate for products of combustion to be removed efficiently An 18 457 mm minimum clearance should be maintained between the flue vent and the filters of t...

Page 8: ...OM THE TANK Tank warranty may be voided by improper operation Turn gas valve off when draining or filling FILL FRY TANK WITH LIQUID SHORTENING CAUTION Before turning the burners on the fry tank must be filled with liquid shortening If this is not done the tank walls can be damaged Warpage can cause leaks Use only liquid shortening Fill fry tank to the oil level line on the back wall Fig 2 DO NOT m...

Page 9: ...ING FOODS Heat shortening to set temperature Pieces of product to be fried should be about the same size to ensure the same doneness Drain or wipe dry raw or wet foods to minimize spatter when lowering into the hot oil Do not overfill baskets Carefully lower baskets into oil When frying doughnuts and fritters turn product only once during frying When cooking French fries or onion rings shake baske...

Page 10: ...east once a day or more often if conditions warrant A commercial power filter available from other manufacturers may be used Follow the manufacturer s operating instructions for draining straining and replacing shortening in the fry tank Another way to filter is to drain the shortening from the drain pipe through a filter bag or cover the receiving container with cheesecloth or other filtering mat...

Page 11: ...l cleaner following the manufacturer s instructions 3 Set the thermostat at a temperature recommended by the manufacturer of the commercial cleaner and boil the solution for 15 to 20 minutes Monitor boiling to prevent overflow 4 Drain the cleaning solution from the tank 5 Close the drain valve and refill the tank with water Add 1 cup 237 ml of vinegar to neutralize alkaline left by the cleaner Bri...

Page 12: ...the flue when it is cool to be sure it is free of obstructions SERVICE AND PARTS INFORMATION To obtain service and parts information contact the Wolf Range Authorized Servicer in your area listed on our website www wolfrange com or contact the Wolf Range service department at the address or phone number shown on the cover of this manual When calling for service the following information must be av...

Reviews: