Wolf DD30I Planning Information Download Page 4

4

Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

30"

(762) 

Downdraft Ventilation  System

M O D E L S   D D 3 0 I   A N D D D 3 0 R

2

1/8

(54) 

19

1/4

(489) 

COOKTOP CUT-OUT 

DEPTH 

36"

 

(914) 

2

3/8

(60) 

25

1/8

MIN (638) 

OF FLAT COUNTERTOP* 

.344" 

29

5/16

(745) 

 COUNTERTOP 

TO BOTTOM OF 

AIR BOX 

18"

 

(457) 

3

5/8

(92) 

3

1/4

(83) 

5" 

(127) 

7

11/16

(197) 

5/8

(16) 

2

1/2

MIN 

(64) 

WITH NO  

RAISED LIP* 

 

*AREAS OF POTENTIAL INTERFERENCE 

 

 

24" 

MIN (610) 

CABINET DEPTH 

1

3/4

MIN (45) 

BACK EDGE 

OF COOKTOP 
TO INSIDE OF 

CABINET BACK* 

7

1/8

(181) 

30"

min (762)

ELECTRICAL LOCATION

IN CABINET BACK 

E

3

1

/

2

(89)

4"

min (102)

10" 

(254)

24 "

min (610)

CABINET DEPTH

OPTIONAL

ELECTRICAL

LOCATION IN

ADJACENT RIGHT

SIDE CABINET

E

L O C A T I O N   O F E L E C T R I C A L

I N S T A L L A T I O N   S P E C I F I C A T I O N S

Summary of Contents for DD30I

Page 1: ...nframed electric cooktops and are not recommended for use with the electric grill steamer and fryer modules A Pro ventilation hood is recommended for use with Wolf dual fuel ranges gas ranges sealed b...

Page 2: ...lets you know when the filter needs cleaning Delay off feature automatically turns unit off after five minutes chimney remains up Stainless steel filter cover with dishwasher safe aluminum mesh filte...

Page 3: ...Model DD30R see in line and remote blower options below B L O W E R O P T I O N S 1100 CFM In Line Blower 808332 900 CFM Remote Blower 801641 1200 CFM Remote Blower 801642 1500 CFM Remote Blower 80470...

Page 4: ...OP TO BOTTOM OF AIR BOX 18 457 35 8 92 31 4 83 5 127 711 16 197 5 8 16 21 2 MIN 64 WITH NO RAISED LIP AREAS OF POTENTIAL INTERFERENCE 24 MIN 610 CABINET DEPTH 13 4 MIN 45 BACK EDGE OF COOKTOP TO INSID...

Page 5: ...gh space for proper installation 23 8 60 of flat counter top is required behind the cooktop and 13 4 44 is necessary between the back edge of the cooktop and inside of cabinet back The remote mounted...

Page 6: ...R 41 4 108 IN LINE OR REMOTE BLOWER CL NOTE Measurements are to centerline of duct cut outs ADJUSTMENT 5 MAX 127 IN LINE OR REMOTE BLOWER ADJUSTMENT 1 25 7 178 INTERNAL BLOWER 21 2 MAX 165 IN LINE OR...

Page 7: ...E BLOWER 10 ROUND D U C T I N G C O N S I D E R A T I O N S For best performance 10 254 round ductwork is recommended The downdraft will operate most efficiently when ductwork does not exceed 40 12 m...

Page 8: ...r with all Wolf ventilation products In line blowers are mounted in between the downdraft and the exterior of the home Remote blowers can be mounted on the roof or in some cases on an exterior wall Re...

Page 9: ...rnal blower no transition required 31 4 83 x 14 356 duct for in line and remote blowers TRANS 14 10 required for remote blowers C O O K T O P V E N T I L A T I O N B L O W E R O P T I O N S Downdraft...

Reviews: