Wolf gas cooktops are designed to operate

on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP gas at 10" (25 mb) WC
pressure. The minimum line pressure for natural
gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC
for LP gas. The maximum gas supply pressure
to the regulator should never exceed 14"
(34.9 mb) WC; .5 psi (3.5 kPa). It is supplied
with a 

1

/

2

" NPT male gas connection at the

right rear bottom corner of the cooktop. The
male connector exits the unit straight down and
you are supplied with a regulator with two
female connectors.

You must follow all National Electrical Code

and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.

Wolf gas cooktops using natural gas

function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas installa-
tions from 8,000' (2438 m) to 10,000' (3048 m)
need the high altitude conversion kit. LP gas
installations will operate up to 10,000' (3048 m)
without adjustment.

Refer to the installation instructions

shipped with each Wolf product for detailed
specifications.

Planning Information

Integrated Gas Cooktop

M O D E L   C T 1 5 G / S

Dimensions in parentheses are in
millimeters unless otherwise specified.

5

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, cut-out dimensions and
installation specifics.

When multiple integrated cooktop modules

are installed side by side, refer to the counter-
top cut-out dimensions on page 6.

A Wolf downdraft system, Cooktop or

Pro ventilation hood is recommended. When
installing a ventilation hood, refer to the specific
requirements of the hood for the minimum
dimension to countertop. Also refer to the
ventilation recommendation charts in the
cooktop or Pro ventilation sections of our
website, wolfappliance.com.

The Wolf integrated gas cooktop requires a

separate 120 V AC, 60 Hz power supply. The
service should have its own 15 amp circuit
breaker and a grounded 3-prong receptacle
should be located within the reach of the
6' (1.8 m) power cord. Locate electrical within
the shaded area shown in the illustration on
page 4.

IMPORTANT NOTE: 

A ground fault circuit

interrupter (GFCI) is not recommended and may
cause interruption of operation.

For the integrated gas cooktop, the gas

service may be supplied through the floor if the
cooktop is not installed above an oven. Refer
to the illustration on page 4 for placement of
electrical and gas supply.

This cooktop is intended for indoor use only.

Summary of Contents for CT15G/S

Page 1: ...mmer This patented feature allows you to have the slightest of flame and enjoy a simmer with no boiling or scorching The integrated gas cooktop is available in the classic stainless steel finish The sealed burners and deep recess of the seamless drawn pan area make clean up of any of those previ ously unsightly spills a snap With Wolf s integrated modules you have the ultimate in customization You...

Page 2: ...eel finish Two dual stacked sealed burners with automatic reignition on all settings One medium 12 000 Btu hr 3 5 kW sealed burner with 800 Btu hr 2 kW delivered at simmer One small 9 200 Btu hr 2 7 kW sealed burner with 300 Btu hr 1 kW delivered at simmer Individual spark ignition system True Simmer setting on both burners Illuminated control panel with two tiered control knobs Low profile cast i...

Page 3: ... lbs 14 kg Special Note Cooktop can be installed in combination with other cooktops or modules Specifications are subject to change without notice M O D E L O P T I O N S Classic Stainless Steel CT15G S Natural gas model listed for LP gas add LP to the model number V E N T I L A T I O N O P T I O N S 30 762 Cooktop hood or Pro wall or wall chimney hood or liner 30 762 or 45 1143 downdraft ventilat...

Page 4: ...15 381 cooktop or module Minimum clearance from both side edges of cooktop cut out to combustible materials up to 18 457 above countertop Minimum clearance from rear edge of cooktop cut out to combustible materials up to 18 457 above countertop 191 4 489 COOKTOP CUT OUT DEPTH 21 2 min 64 36 914 STANDARD FLOOR TO COUNTERTOP HEIGHT 13 max 330 30 762 COUNTERTOP TO COMBUSTIBLE MATERIALS ABOVE COOKTOP ...

Page 5: ...parentheses are in millimeters unless otherwise specified 5 I N S T A L L A T I O N N O T E S Refer to the illustrations and specifications for overall dimensions cut out dimensions and installation specifics When multiple integrated cooktop modules are installed side by side refer to the counter top cut out dimensions on page 6 A Wolf downdraft system Cooktop or Pro ventilation hood is recommende...

Page 6: ...of multiple cooktop units When two or more cooktops or modules are installed together an accessory filler strip is recommended Refer to Accessories on page 3 Countertop cut out dimensions for installation of multiple cooktop units IMPORTANT NOTE When multiple cooktops and or modules are installed side by side each unit must have its own separate recommended electrical circuit When multiple gas coo...

Reviews: