![Wolf 3064055-201508 Installation Instructions Manual Download Page 46](http://html.mh-extra.com/html/wolf/3064055-201508/3064055-201508_installation-instructions-manual_991843046.webp)
46
BWL-1S-10/14 outdoor module
BWL-1S-10/14 outdoor module
6.
E
E
B
Aperture for condensate drain pipe
(
Caution:
Do not obstruct the aperture
in the condensate pan)
C
Overflow outlet
E
Adhesive aluminium tape
D
End of unheated area on drain heater
Note on 6:
• The end of the unheated area must be positioned at point
D
.
• Only use cable ties to secure the unheated area of the drain heater.
• The drain heater is secured at the bottom of the left-hand motor support.
• Route the heated area of the drain heater as close as possible to apertures
B
and
C
on the floor of the
condensate pan.
• When doing so, secure the drain heater to the floor in 2 places using adhesive aluminium tape.
GB
3064055_201508