821667: VAMP2 Series User Guide
© 2012 Wohler Technologies, Inc. All rights reserved.
18
VAMP2 Series User Guide
Rear Panel Connectors
To monitor
video
from these inputs, set the following:
•
The
Video Source
select button to
SDI
,
•
The
SDI Input
select button to SDI input either (
In 1
or
In 2
), and
•
The
SDI Group
select button to the
SDI Group
of choice (1,
2, 3, or 4).
To monitor
audio
(only) from these inputs, set the following:
•
The
Audio Source
select button to SDI,
•
The
SDI Input
select button input either (
In 1
or
In 2
), and
•
The
SDI Group
select button to the
SDI Group
of choice
(1, 2, 3, or 4).
Even if SDI is not selected for monitoring through the unit, you can
still select the SDI input (
In 1
or
In 2
) and use the re-clocked
SDI
Output
connector and
CVBS Converted Video Output
(from an
SDI input) Connector regardless of other settings. This feature
enables processing of the SDI signal independent of the unit’s other
monitoring functions.
•
SDI Out
(BNC): The output BNC connector outputs a re-clocked
HD/SD-SDI signal derived from the
selected
HD/SD-SDI input.
This output functions regardless of other selection settings enabling
output of the re-clocked HD/SD-SDI signal independent of the
unit’s other monitoring functions (as long as a valid HD/SD-SDI
signal is present at the input).
•
(Optional)
Unbalanced AES Out from SDI
(HD-15): Unbalanced
AES signals de-embedded from the selected SDI input are output
from this HD-15 connector. See
Figure 1–3 on page 19
for the
pin-out for this connector.
Note:
You can request the optional
Unbalanced
AES Out
from SDI HD-15
connector instead of the
Balanced
AES Out from SDI DB-25
connector at the time you
place your order.
USO