Maintenance
36
7
Maintenance
7.1
Regular maintenance
WARNING!
Switch off the machine and disconnect the electric
power before making any adjustment, accessory
assembly and maintenance.
Fig. 14: Lubrication point marked by an
arrrow
Keep the machine well lubricated. Inject the
lubrication oil ISO VG 32 (summer) or ISO VG
68 (winter) into oil holes before and after each
use.
Keep the electric part of the machine from
getting wet. If water accidentally enters the
drain cleaning machine with the cable, remove
the cover and remove the water.
Fig. 15: Clamp jaws, cover removed
Prior to the next use, after being stored for a
long time, check the machine for free rotation,
then turn on the control switch. If the machine
shaft does not rotate after the motor is running
or the handle is pressed, there may be rust in-
side. Turn off the electric power immediately
to avoid electric damage. In this case, send it
to the service or replace the clamp jaws.