Wohler RM-2435-HD User Manual Download Page 4

© 2010 Wohler Technologies, Inc. All rights reserved.

2

 

RM-2435-HD User Guide

Safety Instructions

Safety Instructions

1.

Read, keep, and follow all of these instructions; heed all warnings.

2.

Do not use this equipment near water.

3.

Use only a dry cloth to clean the equipment.

4.

Do not block any ventilation openings. Install only in accordance 

with the instructions in the section entitled, “

Front Panel Controls

” 

on 

page 6

.

5.

Do not install near any heat source such as a radiator, heat register, 

amplifier, or stove.

6.

Do not expose the equipment to rain or moisture.

7.

Do not attempt to plug the unit into a two-blade outlet (with only 

two prongs of equal width). 

8.

Protect the power cord from being walked on or pinched, 

particularly at plug’s source on the equipment and at the socket.

9.

Use only the attachments/accessories specified by the 

manufacturer.

10.

Unplug the equipment during lightning storms or when unused 

for long periods of time.

11.

Refer all servicing to qualified service personnel. Servicing will be 

required under all of the following conditions:

The equipment has been damaged in any way, such as when 

the power-supply cord or plug is damaged.

Liquid had been spilled or objects have fallen onto the 

equipment.

The equipment has been exposed to rain or moisture.

The equipment does not operate normally.

The equipment has been dropped.

IMPORTANT:

By design, these audio/video monitors will only plug into a three-
prong outlet for your safety. If the plug does not fit into your outlet, 
contact an electrician to replace the obsolete outlet. 

Summary of Contents for RM-2435-HD

Page 1: ...f World Leader of In Rack Audio Video Data Monitoring and Closed Captioning Solutions CONFIDENCE IS EVERYTHING RM 2435 HD 2RU 4 Screen 3 5 HD SD SDI and CVBS Audio Video Monitors User Guide Part Numbe...

Page 2: ...ies Inc has tested its equipment and software and reviewed the documentation Wohler Technologies Inc makes no warranty or representation either express or implied with respect to software documentatio...

Page 3: ...l processing support HD SDI and analog composite video standards All video formats are scaled to fit on screen in the highest quality using full digital processing precision scaling and gamma correcti...

Page 4: ...cord from being walked on or pinched particularly at plug s source on the equipment and at the socket 9 Use only the attachments accessories specified by the manufacturer 10 Unplug the equipment duri...

Page 5: ...44 45mm space above and below the unit for air circulation DC Power Connect the unit to its external 100 to 240VAC 50 to 60Hz to 12VDC power supply included Features The RM 2435 HD audio video monito...

Page 6: ...es of depth The feature rich audio video monitors provide all of the following Four 3 5 LCDs Selectable 16 9 or 4 3 screen aspects for on screen video Rack mount mechanical design with vertical tilt A...

Page 7: ...at power up Waveform monitor User defined hot key functionality provides all of the following H V delay toggle through functions Underscan toggle on off On Screen Display OSD on off Color bar on off...

Page 8: ...9 x 3 5 x 2 2 486 x 89 x 56 mm Power Consumption 12VDC 10 Watts 3 8 Amps max CE UL power supply Operating Temperature 0 C 32 F to 40 C 104 F Video Format NTSC PAL auto recognition Inputs HD SD SDI Ana...

Page 9: ...or the assigned left right stereo audio channels with stereo headphones from this mini stereo connector Power Each of the four Power buttons turn the associated LCD screen on and off the LED glows gre...

Page 10: ...this button is used to select the audio source for monitoring through the headphones Press this button on whichever LCD section you wish to audibly monitor and the green LED will light to indicate you...

Page 11: ...S video signals The inputs comply with SMPTE259M SMPTE292M ITU R BT601 Composite video inputs comply with SMPTE 170M RS 485 Reserved for future use Power To provide power to the unit attach the suppli...

Page 12: ...nput signals are automatically detected Audio Levels Levels for the selected eight of 16 audio channels de embedded from an HD SD source are displayed on eight meters Four meters on the left side and...

Page 13: ...EO B AUDIO C MARKER D OSD E USER CONTROL F USER CONFIG 3 Press the Enter button to enter the chosen sub menu 4 Use the Up or Down buttons to cycle through the sub menu selections 5 When the desired op...

Page 14: ...YPE MET 1 L SRC CH 1 CH 1 to CH 16 MET 1 R SRC CH 2 MET 2 L SRC CH 3 MET 2 R SRC CH 4 MET 3 L SRC CH 5 MET 3 R SRC CH 6 MET 4 L SRC CH 7 MET 4 R SRC CH 8 TEST LEV 20 db 20DB to 18DB HEADPHONE ON ON or...

Page 15: ...e STATUS INDICATION STD DISP AUTO OFF ON or OFF TC Time Code DISP ON or OFF WFM waveform Monitor DISP IMD In Monitor Display DISP IMD POS TOP or BOTTOM Note This feature is disabled on models that inc...

Page 16: ...ue The User Button You can use the User button as a hot key Assigning a parameter to this button allows that parameter to be displayed and adjusted on screen at the press of the button without display...

Page 17: ...served 15 RM 2435 HD User Guide Technical Functional Overview UNDER SCAN OSD CONTROL COLOR BAR AUDIO MON AREA MARKER SAFE MARKER Technical Functional Overview The following block diagram illustrates t...

Page 18: ...2010 Wohler Technologies Inc All rights reserved 16 RM 2435 HD User Guide Technical Functional Overview Figure 1 6 RM 2435 HD Block Diagram...