 Wöhler CM 220

1. Important information

Befor e using this instrument, car efully read and observe all notes 

contained in these operating instructions.

Fundamentally , skilled personnel only should use the Wöhler 

CM  220 for the purpose that it is intended and within the speci-

fied data range. No liability is accepted under any cir

cumstances 

or guarantee given for r esults determined in conjunction with this 

instrument nor for any damage that may arise when using this 

instrument.

Recovering time is r equired when the meter was exposed to high 

level CO. The longer the exposur

e, the longer r ecovering time is 

needed.

2. Specification

2.1 Application

The Wöhler CM 220 is a digital pen type CO meter that can be used for do

-

mestic purposes to check fur

naces, r oom heaters, central heating fur naces, 

water heaters etc. as well as for commer

cial purposes, e.g. the ventilation 

contr ol of indoor parking garages.
The electr ochemical sensor garantizes an exact measur

ement even if other 

gases interfer e.  

!

!

!

Wöhler Technik GmbH

 

1.

 

Important information

Summary of Contents for CM 220

Page 1: ...W hler CM 220 Carbon Monoxide Meter The Measure of Technology...

Page 2: ...for any damage that may arise when using this instrument Recovering time is r equired when the meter was exposed to high level CO The longer the exposur e the longer r ecovering time is needed 2 Spec...

Page 3: ...m at 20 5 C 50 20 RH Resolution 1 ppm Power supply 3 pieces AAA Response time within 60 seconds Operating humidity 5 99 RH no condensation Storage condition 20 60 C Operation temperatur e 0 45 C Meter...

Page 4: ...display Max CO value 3 Battery indicator low battery 3 2 Function keys 1 Turn on and of f the backlight Switch temperatur e unit C and F Reset the maximum CO value 2 Turn the meter on and of f Select...

Page 5: ...cause failure in passing Self Test 4 2 Switch temperature units Users can select C or F as the temperatur e unit by pr essing the backlight key see fig 3 2 key 1 for more than 1 second during the sel...

Page 6: ...is case you have to change the batteries 4 7 Auto power off The meter tur ns itself of f automatically after 15 minutes non operation It will not auto power of f during the calibration 5 0 ppm Calibra...

Page 7: ...ry indicator was shown before the display disappear ed r eplace a new battery Calibration failur e If the low battery indicator was shown before the calibration r eplace a new battery E 2 The value is...

Page 8: ...ay hand in any defective batteries taken out of the unit to our company as well as to r ecycling places of public disposal systems or to selling points of new batteries or storage batteries In the Eur...

Page 9: ...ur opean Council for to adapt the legal pr ovisions of the Member States in r espect of electr omagnetic compatibility 2014 30 EU The following standar ds wer e availed of to evaluate the pr oduct in...