Section 1: General Features and Specifications

Installation

Mounting

The unit should be mounted where convenient for operating persons, ideally at approximately ear/eye level for best high frequency
response and visual observation of the level meters. Its superior magnetic shielding eliminates concerns about locating it adjacent to
most types of CRT monitors, including even high-resolution color monitors.

NOTE:

 Be sure to set the level meter Input Level Gain Calibration and VU/PPM Display Mode DIP switch (accessed through the top

cover) BEFORE installing the unit into an enclosed rack or console. See page 17 for setting information.

Heat Dissipation

Heat dissipated by the speaker amps is conducted directly to the left side of the chassis; no special considerations for cooling are
necessary as long as the ambient temperature inside the rack area does not exceed approximately 40°C (104°F).

Sympathetic Vibration

Sympathetic vibration from other equipment (cables, etc.,) in the rack may be serious enough to interfere with the unit’s sound quality
out in the listening area. The use of thin card stock and/or felt or foam weather-stripping type materials between adjacent vibrating
surfaces, or tying up loose cables, etc., may be required to stop vibrations external to the unit.

Mechanical Bracing

Even though the unit is fairly heavy, the chassis is securely attached to the front panel at eight points along its surface, not just at
the four corners of the chassis ears. This feature will reduce or eliminate rear bracing requirements in many mobile/portable applica-
tions.  The weight of internal components is distributed fairly evenly around the unit.

Audio Connections

Connection of the audio feeds is straightforward. Please refer to the system interconnect block diagrams on pages 20 and 21 for
clarification of the general signal paths into and out of the AMP2A and AMP2A-2S units.

Analog inputs via the 3-pin female XLR connectors are configured for 200K 

 balanced connections.  RCA connector inputs

(AMP2A only) are configured for 47K 

 unbalanced connections.

Electrical Interference

Care should be exercised to avoid mismatched cable types and other similar causes of undesired reflections in RF signal systems.  If
severe enough, such reflections can result in undesirable electrical interference in the audio signals.

As with any audio equipment, maximum immunity from electrical interference requires the use of shielded cable; however, satisfactory
results can sometimes be obtained without it.  The internal circuitry common is connected to the chassis.

AC Power

The unit's AC mains connection is via a standard IEC inlet, with safety ground connected directly to the unit's chassis.  The universal
AC input (100-240VAC, 50/60Hz) switching power supply is a self-resetting sealed type, with automatic over-voltage and over-current
shutdown.  There is no user-replaceable fuse in either the primary or secondary circuit.

Summary of Contents for AMP1-DA

Page 1: ...odulePCBCircuitDescription GeneralLevelMeterPCBDescriptions SeriesIILevelMeterRearPanelDIPSettings SeriesIILevelMeterInternalDIPSettings SeriesIILevelMeterInternalDIPLocations Mute on Error Header H12...

Page 2: ...ing walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only wi...

Page 3: ...1 DA User Manual P N 821530 Rev C 2006 Wohler Technologies Inc ALL rights reserved 3 General Features and Specifications Description Features Applications Specifications Other Options Section 1 12 01...

Page 4: ...the selected stereo inputs An additional pair of XLR connectors are provided on the rear panel for outputing an analog signal of the selected sources for connecting to downstream equipment AMP1 D AMP...

Page 5: ...subject to improvement without notice Other Options Wohler Technologies offers the broadest range of standard production audio monitor units Standard production models or special order customfeatures...

Page 6: ...unit is fairly heavy the chassis is securely attached to the front panel at eight points along its surface not just at the four corners of the chassis ears This feature will reduce or eliminate rear...

Page 7: ...r Manual P N 821530 Rev C 2006 Wohler Technologies Inc ALL rights reserved 7 Operation Front Panel Features Rear Panel Features Audio Amplifier and Speaker Configuration Balance Control Characteristic...

Page 8: ...red glow of the larger LED almost always indicates an out of phase alarm condition Audio Level Meters Audio levels for the selected input sources are displayed via these two 26 segment tri color GREE...

Page 9: ...C 2006 Wohler Technologies Inc ALL rights reserved 9 Section 2 Operation Figure 2a Front Panel Features AES WOHLER TECHNOLOGIES POWER 1 2 SOURCE AVG AES1 AES2 ANALOG DIGITAL MONITOR PANEL AMP1 DA DIGI...

Page 10: ...will create a red error indication in the AES EBU Signal Status Indication LED 1 Reception errors errors in reception of data or no data stream at all 1 DOWN or 2 Reception and data errors errors in r...

Page 11: ...AMP1 DA User Manual P N 821530 Rev C 2006 Wohler Technologies Inc ALL rights reserved 11 Figure 2b Rear Panel Features Section 2 Operation...

Page 12: ...bration feature the Display Mode and the Reference Level for the Audio Level Meters Item 6 page 8 See page 18 for information on setting these parameters Note An internal DIP switch module sets the Pe...

Page 13: ...AMP1 DA User Manual P N 821530 Rev C 2006 Wohler Technologies Inc ALL rights reserved 13 Section 2 Operation Figure 2b Rear Panel Features...

Page 14: ...the AMP1 Series audio amplifier speaker configuration Balance Control Characteristics The balance control attenuates the signal from the source so that the left and right bass frequencies summed toge...

Page 15: ...escriptions Series II Level Meter Rear Panel DIP Settings Series II Level Meter Internal DIP Settings Series II Level Meter DIP Locations AMP1 DA Interconnect Block Diagram Section 3 NOTE PCB layout a...

Page 16: ...e and before the volume control section The signal pick off for the headphones is after the volume and balance controls Speaker muting is controlled by circuitry that senses connection of headphones t...

Page 17: ...1 open See Item B page 10 for more information regarding this setting An additional feature of the AES signal error detection is the ability to mute the audio when errors are detected in the AES sign...

Page 18: ...is 4 dB See DIP switch diagram below for settings Bargraph Display Mode DIP switch sections 4 and 5 determine how peak levels are displayed for the associated meters on the front panel There are four...

Page 19: ...dB Integration Rise Time is 10 ms 2 dB Return Fall Time is 2 8 seconds 24 dB Integration Rise Time is 5 ms 2 dB Return Fall Time is 1 5 seconds 20 dB Integration Rise Time is a single sample Return F...

Page 20: ...er Technologies Inc ALL rights reserved 20 Section 3 Technical Information Level Meter DIP Module Locations 919174 PCB Internal Level Meter 10 Position DIP Switch Module see page 19 Rear Panel Level M...

Page 21: ...Location 919117 PCB Installing a jumper at H12 will mute the audio if errors are detected See page 14 for more information Installingajumperat H12 will enable the audio to mute when errors in the AES...

Page 22: ...AMP1 DA User Manual P N 821530 Rev C 2006 Wohler Technologies Inc ALL rights reserved 22 AMP1 DA Interconnect Block Diagram...

Page 23: ...AMP1 DA User Manual P N 821530 Rev C 2006 Wohler Technologies Inc ALL rights reserved 23 Section 3 Technical Information...

Page 24: ...21530 Rev C 2006 Wohler Technologies Inc ALL rights reserved 24 Wohler Technologies Inc 31055 Huntwood Avenue Hayward CA 94544 Phone 510 870 0810 Fax 510 870 0811 US Toll Free 1 888 596 4537 www wohle...

Reviews: