Operation manual PEK
Page 19 of 25
B0053
Connect the outlets of the pump elements with the lube lines. Deliver into the lube lines. You
may not connect the lube lines to the lube points unless the lubricant comes out free of air.
Check all connections of the lube lines for tightness.
Warning!
The applied pipelines have to be designed for an operating
pressure of 32 bar
6.6 Shutdown
The unit is shut down by switching the compressed air supply off.
7. Operation
7.1 Refilling the reservoir
The lid of the reservoir is to be used for refilling the pump.
Important!
Versions without filling level monitoring require the checking of
the reservoir's filling level in regular intervals (intervals depend-
ing on consumption).
To ensure flawless functioning, the filling level must not be
lower than 10-15
mm above the reservoir’s bottom edge.
7.2 Switch-off
The PEK is switched off by disconnecting it from the compressed air supply.