Manual  -MD150T – 27.10.2014 – v.1.3 

   page 7 

 

3.

 

Menu description 

3.1

 

MENU map 

 

     000000

     

-> 

  

displaying of current measurement  value 

 

 

Menu entry 

 

 

 

 

Min. measurement value display 

 

 

 

Max. measurement value display 

 

 

(3 sec.)  Zeroing of min/max 

measurement value

 

      1.     P1

           

 ->

    Menu 

 

Next/previous 

parameter 

 

 

 

          

parameter selection 

 

Digit selection 

Change value 

Parameter edition 

1. 

P1 

PK1 relay threshold   

R

el

ays

 

± 999999 

2. 

P2 

PK2 relay threshold   

± 999999 

3. 

P3-H 

Relays switching on/off hysteresis  

± 999999 

4. 

MODE 

Relays operational mode  

mode 0  / 1 

5. 

TARA 

Zeroing of sensor indications 

Me

as

u

re

me

n

ts

 

 

6. 

OFFS 

Offset for measuring value 

± 999999 

7. 

UNIT 

Units    

N, kN, g, kg, T, funt 

8. 

RATE 

Measurement frequency 

10 Hz / 80 Hz  

9. 

FILT 

Level of averaging continuous filter 

0…99 

10. 

TRA 

 

Bridge range

 [N] configuration parameter 

0..999999 

11. 

TSE 

Bridge constant

 [mV/V] configuration parameter 

0..99.9999 

12. 

DP 

Number of decimals of the result

 

0..3 

13. 

ADR 

 MODBUS address 

R

S485

 

0-99 

14. 

BAUD 

MODBUS baud rate 

9600 / 19200 / 38400 

57600 / 115200 

15. 

BEP 

Keys audible signal  

O

th

er

 

On / OFF 

16. 

LED 

Display brightness level 

0-9 

17. 

FAC 

Restoring factory default settings  

 

18. 

PAS 

Password 

X-0000 - not active 

 

 

 

Menu exit/abortion 

 

    

      

        

Parameter confirmation/abortion 

 

 
 

 

Blinking measurement value means exceeding of sensor rated load

  (more information- chapter 

Błąd! Nie można odnaleźć źródła odwołania.).

 

 

Summary of Contents for MD150T

Page 1: ...t E J K s c D borzyce 16 62 045 Pniewy tel 48 61 22 27 422 fax 48 61 22 27 439 e mail wobit wobit com pl www wobit com pl MD150T Manual Digital processing unit with display for force sensors without a...

Page 2: ...s 13 9 2 Measuring range of sensor 13 10 Technical parameters 14 Thank you for selecting our product This instruction will help you at correct service and accurate exploitation of described device Inf...

Page 3: ...nments of unknown levels of interruptions it is recommended to use the following means preventing against possible interruptions of the device operation Ground or zero the metal rails on which instrum...

Page 4: ...iguration and recording measurement data in PC e g to Excel file with the use of MD150 PC software MODBUS RTU allows for reading of measurements from several indicators at the same time to PLC control...

Page 5: ...sensor Signal 3 S Signal sensor Signal 4 E Power supply sensor Excitatnion 5 TARA Tare input 5 24V 6 DIN2 Universal input 7 485A A Signal of RS485 interface 8 485B B Signal of RS485 interface 9 10 PK1...

Page 6: ...White White Yellow Green Tab 1 Description of cable colors for force sensors of WObit s offer CAUTION In longer period of time can happen that derivation colors can change Wrong connection do not caus...

Page 7: ...asurements 6 OFFS Offset for measuring value 999999 7 UNIT Units N kN g kg T funt 8 RATE Measurement frequency 10 Hz 80 Hz 9 FILT Level of averaging continuous filter 0 99 10 TRA Bridge range N config...

Page 8: ...key you confirm the introduced change and with key you abort the change or exit the menu Prolonged pressing of keys or results in automatic increase decrease of a given position value 4 Configuration...

Page 9: ...Units of measurement are set by 7 UNIT parameter The user has following units for selection 1 N Newton s 2 kN kilonewtons 2 g grams 3 kg kilograms 4 T tones 5 Funt pound Additionally 12 DP parameter...

Page 10: ...s set with the first digit and the last 4 digits are used for password entry 0 0000 4 digit password 0 9999 Protection level 0 Settings protection above 12 DP parameter 1 Settings protection above 3 P...

Page 11: ...ferrite beads at the cable beginning and its end Use of optically insulated USB hubs at PC side In the conditions of severe interference e g high interference of power grid the communication may not b...

Page 12: ...ppropriate conversion Conversion of 2 registries 4 Byte into 32 Bit number REAL Registry_2 HI Byte1 Registry_2 LO Byte0 Registry_3 HI Byte3 Registry_3 LO Byte2 Number _32_bit Byte3 24 Byte2 16 Byte1 8...

Page 13: ...ge tension force Range of measured force 0 75kN Example of models K1401 K1501 K1505 K1506 K1600 Round To measure large and small tension force Range of measured force 0 100kN Example of models KB52 KB...

Page 14: ...zero tolerance 2 of measuring range hysteresis 0 2 of range and creep measured in time of 30 minutes 0 1 Temperature factor of zero point and constant is 0 1 of range 10o C Bridge resistance on input...

Reviews: