background image

 

www.wobit.com.pl 

Manual  -MD150T – 27.10.2014 – v.1.3 

   page 5 

 

2.2

 

Description of connectors and front panel 

Front panel 

 

LED1 

- indicator of PK1 relay activation  

LED2 

- indicator of PK2 relay activation 

ESC 

- abortion, Reset 

DOWN 

- next menu position/next parameter digit 

UP 

- previous menu position / digit value increase   

ENTER 

- menu entry/confirmation of entered changes  

Back panel 

 

E+ 

Power  sensor (Exci) 

S+ 

 sensor ()  

S- 

Signal- sensor(Signal-) 

E- 

Power supply- sensor (Excitatnion-) 

TARA 

Tare input (+5..+24V)   

DIN2 

Universal input 

485A 

A Signal of RS485 interface 

485B 

B Signal of RS485 interface 

9,10 

PK1 

PK1 (NO) relay contacts 

11,12 

PK2 

PK2 (NO) relay contacts 

13 

V+ 

12-36 VDC power supply, min. 250mA 

14 

GND 

Power supply mass 

2.3

 

Force sensor connection

 

MD150T  digital  processing  unit  can  be  integrated  with  any  force  sensor,  which  has  input  with 
resistance  of  standard  bridge  bigger  than  150Ω.    Sensor  should  be  connect  according  to  scheme 
below.  

 

Picture. 2 

Way of connecting force sensor to  MD150T digital processing unit 

 

Summary of Contents for MD150T

Page 1: ...t E J K s c D borzyce 16 62 045 Pniewy tel 48 61 22 27 422 fax 48 61 22 27 439 e mail wobit wobit com pl www wobit com pl MD150T Manual Digital processing unit with display for force sensors without a...

Page 2: ...s 13 9 2 Measuring range of sensor 13 10 Technical parameters 14 Thank you for selecting our product This instruction will help you at correct service and accurate exploitation of described device Inf...

Page 3: ...nments of unknown levels of interruptions it is recommended to use the following means preventing against possible interruptions of the device operation Ground or zero the metal rails on which instrum...

Page 4: ...iguration and recording measurement data in PC e g to Excel file with the use of MD150 PC software MODBUS RTU allows for reading of measurements from several indicators at the same time to PLC control...

Page 5: ...sensor Signal 3 S Signal sensor Signal 4 E Power supply sensor Excitatnion 5 TARA Tare input 5 24V 6 DIN2 Universal input 7 485A A Signal of RS485 interface 8 485B B Signal of RS485 interface 9 10 PK1...

Page 6: ...White White Yellow Green Tab 1 Description of cable colors for force sensors of WObit s offer CAUTION In longer period of time can happen that derivation colors can change Wrong connection do not caus...

Page 7: ...asurements 6 OFFS Offset for measuring value 999999 7 UNIT Units N kN g kg T funt 8 RATE Measurement frequency 10 Hz 80 Hz 9 FILT Level of averaging continuous filter 0 99 10 TRA Bridge range N config...

Page 8: ...key you confirm the introduced change and with key you abort the change or exit the menu Prolonged pressing of keys or results in automatic increase decrease of a given position value 4 Configuration...

Page 9: ...Units of measurement are set by 7 UNIT parameter The user has following units for selection 1 N Newton s 2 kN kilonewtons 2 g grams 3 kg kilograms 4 T tones 5 Funt pound Additionally 12 DP parameter...

Page 10: ...s set with the first digit and the last 4 digits are used for password entry 0 0000 4 digit password 0 9999 Protection level 0 Settings protection above 12 DP parameter 1 Settings protection above 3 P...

Page 11: ...ferrite beads at the cable beginning and its end Use of optically insulated USB hubs at PC side In the conditions of severe interference e g high interference of power grid the communication may not b...

Page 12: ...ppropriate conversion Conversion of 2 registries 4 Byte into 32 Bit number REAL Registry_2 HI Byte1 Registry_2 LO Byte0 Registry_3 HI Byte3 Registry_3 LO Byte2 Number _32_bit Byte3 24 Byte2 16 Byte1 8...

Page 13: ...ge tension force Range of measured force 0 75kN Example of models K1401 K1501 K1505 K1506 K1600 Round To measure large and small tension force Range of measured force 0 100kN Example of models KB52 KB...

Page 14: ...zero tolerance 2 of measuring range hysteresis 0 2 of range and creep measured in time of 30 minutes 0 1 Temperature factor of zero point and constant is 0 1 of range 10o C Bridge resistance on input...