WIZ620wi User’s Manual
(WIZnet Co., Ltd.)
53
QI
Get Inactivity Time
00~60
<Sxx>
OI
Set Inactivity Time
00~60
<xx>
QU
Get
TCP Connection
Option
0-1
0: Try the “TCP connection” at the TCP Client mode
regardless of serial data input
1: Try the TCP connection” at the TCP Client mode
when serial data is received
<Sx>
OU
Set
TCP Connection
Option
0-1
0: Try the “TCP connection” at the TCP Client mode
regardless of serial data input
1: Try the TCP connection” at the TCP Client mode
when serial data is received
<Sx>
RU
Get Get Aux Port
Enable[_Protocol_Mode_ServerIP or
Domain_ServerPort]
Enable: 0(Disable), 1(Enable), If Disable is set, data can
be omitted.
Protocol: 0(UDP), 1(TCP)
Mode: 0(Server), 1(Client)
ServerIP: a.b.c.d format
Domain: xxx.yyy.zzz
ServerPort: 0-65535
<Sx_x_x_a.b.c.d_x>
WU
Set Set Aux Port
Enable[_Protocol_Mode_ServerIP or
Domain_ServerPort]
Enable: 0(Disable), 1(Enable), If Disable is set, data can
be omitted.
Protocol: 0(UDP), 1(TCP)
Mode: 0(Server), 1(Client)
ServerIP: a.b.c.d format
Domain: xxx.yyy.zzz
ServerPort: 0-65535
<x_x_x_a.b.c.d_x>