Operation
Original operation manual
HIGH PRESSURE CLEANER
HPC_BADBK_en_1805 • rs
30
5 Operation
Prerequisites:
➤
The high pressure cleaner must be correctly installed and connected
to a suitable compressed air or hydraulic supply.
➤
Only put the high pressure cleaner into operation if you are equipped
with the prescribed protective equipment. Details on this can be found
in chap. 2.5.4 on page 16.
➤
The cleaning solution must be available in sufficient quantity.
5.1 Putting the device into operation
Checklist prior to commissioning:
➤
Check if a system separator is necessary to protect the drinking
water.
➤
Check if all safety features are present and fully functional.
➤
Check the release agent level of the high pressure pump and refill it if
necessary.
➤
During commissioning, check if all parts of the high pressure cleaner
are leak-tight and tighten the connections if necessary.
➤
Make sure that the high pressure cleaner is properly grounded
(see chap. 4.3.2 on page 28).
1.
Place the suction in the container with the cleaning solution.
2.
Make sure that the compressed air regulator is turned all the way down.
3.
Open the compressed air shut-off valve.
4.
Set the compressed air regulator to approx. 2 bar.
5.
Hold the high pressure cleaner gun into a collecting vessel.
6.
Release the high pressure cleaner gun and fire it until pure cleaning
solution escapes.
7.
Set the required working pressure on the compressed air regulator.
5.2 Relieving the pressure
1.
Close the compressed air shut-off valve.
2.
Hold the high pressure cleaner gun into a collecting vessel.
3.
Release the high pressure cleaner gun and fire it until the spraying
pressure is completely relieved.
4.
Let go of the high pressure cleaner gun trigger and engage the
trigger lock.