background image

 

 

WT-2009 IP65 GSM-AUTO 

WT-2009 IP65 GSM-AUTO – USER MANUAL – Rev. 1.0  

#CSQ 
Check GSM signal strength 
This command is useful to see what the GSM network signal strength is at the location of the unit 
 
To check the signal strength of the location of the unit you would send the following SMS text message to 
the unit #PWD121212#CSQ? 
 
You will receive an SMS with signal quality in range 0 to 31, minimum signal strength of 5 is required, if it 
is below 5 then a change of network is advised. 
 
You will receive the following similar confirmation from the unit #CSQ<22> 
 
#GOT  
Relay ON time 
This is the command that allows you to reset the default ON time of relays. 
To change the default value, you can send the following text command by SMS text message specifying 
the number of seconds the relay should stay on when it is called. 
It is possible to latch each relay for up to a maximum of 65,535 seconds. 
 
To set relay 1 to switch on for 15 minutes each time the unit is called, the following SMS text message is 
sent to the unit. #PWD121212#GOT1=00900 
 
Where 1 indicates relay number 1 and 00900 is the relay on time in seconds, this should be entered in 5 
digits format as shown 
You will receive the following similar confirmation from the unit #GOT1=00900 
 
To set relay 2 to switch on for 10 minutes each time the unit is called, the following SMS command is sent 
to the unit. #PWD121212#GOT2=00600 
 
Where 2 indicates relay number 2 and 00600 is the relay on time in seconds, this should be entered in 5 
digits format as shown 
You will receive the following similar confirmation from the unit #GOT2=00600 
 
#GOTS 
This is the command that allows you to set the delay time between Relay 1 switching off and Relay 2 
switching on. To set the delay time between relay 1 switching off and 2 switching on by 5 seconds, you 
send the following command by SMS text message to the unit. #PWD123456#GOTS=00005 
Where 00005 is the delay time in seconds and should be entered in 5 digits format as shown 
 
You will receive the following similar confirmation from the unit #GOTS=00005 
 
#GOT? 
To check the relay on and delay times you would send the following SMS text message to the unit 
#PWD121212#GOT? 
 
You will receive the following similar confirmation from the unit. 
GOT1:00900 
GOT2:00600 
GOT3:00005 
 
 

Summary of Contents for WT-2009

Page 1: ...at connects to the GSM cell phone network It is activated by calling its cell phone number it will reject the call without answering and switch on the device connected to it There are no call charges...

Page 2: ...to access the SIM card carrier gently push the button adjacent to it insert the SIM card and carefully close the carrier connect the antenna Connect a 12 volt DC power supply to terminal 1 2 ensuring...

Page 3: ...mum current of 1 Amp 3 COMMON COM 4 NORMALLY CLOSED N C 5 NORMALLY OPEN N O RELAY 2 6 NORMALLY CLOSED N C 7 NORMALLY OPEN N O 8 COMMON COM RELAY 1 Example Connections HEATER 110V ac LIGHT 110V ac 1 2...

Page 4: ...paces or any other characters Programming Commands If you are familiar with the commands a quick reference can be found on page 10 PWD Password This command must always pre fix any SMS text commands t...

Page 5: ...r PWD121212 WHL01 27829595 You will receive the following confirmation from the unit WHL01_OK This is the first number in the White list and number 2 is sent as WHL02 and so on up to a maximum of 99 n...

Page 6: ...212 TEL1 07827829595 You will receive the following confirmation from the unit TEL1 07827829595 To check all the administrator number in the list you would send the following SMS text message to the u...

Page 7: ...00900 Where 1 indicates relay number 1 and 00900 is the relay on time in seconds this should be entered in 5 digits format as shown You will receive the following similar confirmation from the unit GO...

Page 8: ...is the on time in seconds this should be entered in 5 digits format as shown You will receive the following confirmation from the unit RLY2 ON 00360 when relay 2 switches on and the following confirma...

Page 9: ...lowing confirmation from the unit SMW 00 00 21 01800 1 1 To program the output relay 2 to turn on for 1 hour at 6am you would send the following SMS text message to the unit PWD123456 SMW 00 00 06 036...

Page 10: ...rity Access Mode ACM ACM2 ACM0 On Off Administrator List TEL TEL1 827829595 Position telephone number Up to 16 digits Up to 8 numbers Check signal strength CSQ CSQ 0 31 minimum 5 required Relay ON tim...

Page 11: ...e to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception...