background image

WITURA

 

TECHNOLOGY

 

SDN

 

BHD

 

|

                                

WT

1672B

 

GSM

 

Wireless

 

Alarm

 

System

 

User

 

Manual

 

V2.0

12

 

Step

 

3

 ‐ 

Installation

  

 

Insert

 

the

 

SIM

 

card,

 

to

 

access

 

the

 

SIM

 

card

 

carrier

 

gently

 

push

 

the

 

button

 

adjacent

 

to

 

it,

 

insert

 

the

 

SIM

 

card

 

and

 

carefully

 

close

 

the

 

carrier

   

Connect

 

the

 

cable

 

to

 

terminals

 

220V

 

&

 

N

 

ensuring

 

positive

 

is

 

connected

 

to

 

terminal

 

200V,

 

switch

 

on

 

the

 

power

 

supply

 

,

 

the

 

red

 

power

 

LED

 

will

 

light

 

indicating

 

power

 

is

 

present,

 

the

 

blue

 

network

 

LED

 

indicator

 

will

 

initially

 

flash

 

quickly,

 

once

 

logged

 

onto

 

the

 

network

 

,

 

it

 

will

 

flash

 

more

 

slowly

 

approximately

 

one

 

every

 

3

 ‐

4

 

seconds

  

It

 

is

 

recommended

 

that

 

the

 

GSM

 

Remote

 

Control

 

Switch

 

be

 

programmed

 

to

 

operate

 

as

 

required

 

before

 

final

 

installation.

   

Connection

 

Details

  

If

 

you

 

are

 

unsure

 

how

 

to

 

connect

 

the

 

device

 

you

 

wish

 

to

 

control

 

refer

 

to

 

a

 

qualified

 

person

   

Connector

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

Board

 

Label

 

12V

 

IN

 

LINE

 

5V

 

OUT

 

RELAY

 

Description

 

12V

 

Power

 

Supply

 

Dry

 

Contact

 

Input

 

Power

 

Outage

 

Alarm

 

Relay

 

Output

 

Details

 

   

+

 

‐ 

 

 

   

+

 

‐ 

 

 

 

Summary of Contents for WT-1672B

Page 1: ...WITURA TECHNOLOGY SDN BHD WT 1672B GSM Wireless Alarm System User Manual V2 0 1 WT 1672B GSM Wireless Alarm System USER MANUAL VERSION 1 2 UPDATED AUG 2013...

Page 2: ...nents like contacts motion sensors remote control and more of these include GSM modules which allow the system to interact with a home owner s mobile device by sending a text message or call to the ow...

Page 3: ...to the unit your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit Administrator 1 18617185300 your phone number 2 3 4...

Page 4: ...he button FACTORY at the mother board until you hear the du This means the unit back to the factory default This means you already reset the unit to factory default Now you can start to call again to...

Page 5: ...the factory password to your new password Enter the factory password follow by your new password 3 Add telephone number into the admin list 1 1 telephone number For example set Admin number 1861718530...

Page 6: ...l CSQ 25 32 Signal Excellent System working well 8 Checking the list of Wireless Alarm that already added to the system 6 Equipment 1 73c704 2 73c708 3 73c702 4 73c701 5 6 7 8 9 2013 10 10 16 14 Thu C...

Page 7: ...you want to activate the alarm function just enter 10 1 When Deactivate Alarm Function is equal to using the Remote Control to disarm The D7 Green LED light in the system will turn off All the functio...

Page 8: ...m to text you for any acknowledgement after you call to the unit You can switch OFF the text message Some Customer request this function because texts reply involved call cost 16 Security mode Open Mo...

Page 9: ...ng it will overwrite the before setting and take the last setting Factory Default as N 0 which means any alarm alert from the equipment it will not call admin number 19 Edit Input Messages for the sys...

Page 10: ...ll return a SMS with Blank Message 21 Delete input messages programmed in the system and the 9 channels wireless alarm alert messages 28 NN When Setting as 28 00 Delete OK 2013 10 10 17 42 Thu After d...

Page 11: ...ich means successful pairing the remote control with the system If Admin Numbers been programmed all the admin number will receive the SMS Message of the Pairing Remote Control location When hear 3 TI...

Page 12: ...ED will light indicating power is present the blue network LED indicator will initially flash quickly once logged onto the network it will flash more slowly approximately one every 3 4 seconds It is r...

Page 13: ...uction Specifications Operation Voltage 12 volts DC Operating Current Maximum 500mA typically 55mA Relay Contacts 2amps GSM Frequency MHz GSM900 1800Mhz or GSM850 900 1800 1900Mhz Humidity Less Than 8...

Page 14: ...e PIN request status of your SIM card place the card in an unlocked mobile phone switch the phone on If you are able to make calls without entering a PIN number the PIN request is disabled If a PIN nu...

Page 15: ...es when program the administrators number Ensure your telephone number is in the Administrator list and that sending text messages to your number is enabled 4 I am not receiving any text messages when...

Page 16: ...n ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper app...

Reviews: