background image

-------------------------  

  -------------------------

 

 

 

Installation Sheet

 

Page PM.10.002886.EN.006

 

 

WSE 81 PLUS and WSE EVO 

Date 

08.02.2016 

 

P/No: 

500 852GB/Version 1 

 

 

 

 

 

Technical Details – Model  WSE 81 PLUS 

 

Technical Details – Model  WSE EVO 

Dimension 

10 mm x 33,5 mm x 2005 mm 

10 mm x 33,5 mm x 2005 mm 

Connection cable 

4 m on transmitter TX and receiver RX  

4 m on transmitter TX and receiver RX 

Fixing kits supplied 

10 x 6mm Plastic Clips 
10 x Nr. 8 x 12 mm S/T screws 
6 x Nr. 6 x 16 mm self-drill screws 
6 x M3.5 Shakeproof washers 

10 x 6mm Plastic Clips 
10 x Nr. 8 x 12 mm S/T screws 
6 x Nr. 6 x 16 mm self-drill screws 
6 x M3.5 Shakeproof washers 

Distance between bottom  
beam and bottom of 
housing 

25 mm 

20 mm 

Distance between top beam 
and bottom of housing 

1808 mm 

1629 mm 

Monitoring range 

4 m 

3.5m 

Number of diodes /detector  18 

46 

Distance between Diodes 

bottom 4 Diodes 61mm, top 4 Diodes 91.5mm, other 10 
Diodes 122mm 

bottom 24 Diodes 61mm, top 8 Diodes 45,7mm 

Number of beams 

84 on detector distance more as 500mm, 
52 on less than 500mm and 18 on less than 200mm 
 

174 on detector distance more as 500mm, 
94 on less than 200mm 

Supply voltage 

11 – 42 V DC continuous, @max. 100 mA, max peak 44V 

11 – 42 V DC continuous, @max. 100mA, max peak 44V 

Output signal 

N/C or N/O Voltage free relay contact,  V=Max. 45VAC, 
current = Max. 0,35A, Max. ON Resistance = 2 Ohm 

N/C or N/O Voltage free relay contact, V=Max. 45VAC, 
current = Max. 0,35A, Max. ON Resistance = 2 Ohm 

Diagnostic LED 

1 red LED in receiver detector RX (visible through lens) 

1 red LED in receiver detector RX (visible through lens) 

Light immunity 

> 100.000 Lux 

> 100.000 Lux 

Operation temperature 

–10 °C to 60 °C as perBS2011, part 2.1 Ab and part2.2 Bb  

–10 °C to 60 °C as perBS2011, part 2.1 Ab and part2.2 Bb  

Storage temperature 

–25 °C to +60 °C; 24 hours maximum on each temperature   –25 °C to +60 °C; 24 hours maximum on each temperature  

High temperature / high 
humidity 

93% BS2011, part 2.1 Db: 1981, Variant 2 at +55 °C 

93% BS2011, part 2.1 Db: 1981, Variant 2 at +55 °C 

EMC conformity 

Emissions to  EN 12015, immunity to EN 12016 

Emissions to  EN 12015, immunity to EN 12016 

IP rating 

IP65 in accordance with BS EN 60529: 1992 

IP65 in accordance with BS EN 60529: 1992 

Vibrations 

Random vibration: 20 to 500 Hz 0,002 g²/Hz 4 hours per 
axis  
Sinusoidal vibration: 30 Hz 3,6 g  30 min per axis 

Random vibration: 20 to 500 Hz 0,002 g²/Hz 4 hours per 
axis  
Sinusoidal vibration: 30 Hz 3,6 g  30 min per axis 

 

 
 
 

 
 
 
 

 

Summary of Contents for WSE 81 PLUS Series

Page 1: ...xcerpts needs the written Authorization of the WITTUR Austria Ltd We reserve the right to make alterations with respect to the specifications and figures in this manual INSTALLATION The systems can be installed either on the moving doors or statically in a position on the end of the door sill a Dynamic Installation The system is mounted on the car doors using the dynamic fixing kit provided 1 Posi...

Page 2: ...eed 42V DC under any circumstances Peak ripple voltage should not exceed 42V and average voltage not exceeds 42V Sufficient power the supply must be capable of supplying at 100mA plus whatever current is needed to drive the door re open circuit on the lift Note if you have any doubts then you should use a WLS power supply IMPORTANT 1 Do not shorten cables by cutting them 2 Ensure that all cables a...

Page 3: ...00 852GB Version 1 Figure 3 Connection diagramm ECO MIDI SUPRA door controller If you are using the WLS power supply unit PLEASE USE TAPE FOR INSULATING THE GREEN WIRE TO AVOID A SHORT CIRCUIT IN THE WLS POWERSUPPLY UNIT X16 X15 Transmitter A Receiver B yellow red blue black black red green ...

Page 4: ...utput switches SW2 and SW3 to be set for detector configuration Relay Output Single pole changeover with hard silver contacts Maximum switching current 5 amps at 240V AC Housing High impact strength plastic box 130x100x45mm Connections Screw terminal blocks Audible Tone Fitted with a beeper and beeper ON OFF switch RXCableconnection WLS Switch Setting 0V 12V TRG LNK NPN N C Green Black Red Blue Ye...

Page 5: ...paque tape is removed When the 20 second timeout has completed the detector will switch back to normal mode so at the next power cycle it will not go into learning mode but it will remember those beams which need to be disabled To re enable learning mode the detector must be switched on with ALL the beams including previously disabled beams unobstructed To prevent the detector from having the lear...

Page 6: ...0mm Supply voltage 11 42 V DC continuous max 100 mA max peak 44V 11 42 V DC continuous max 100mA max peak 44V Output signal N C or N O Voltage free relay contact V Max 45VAC current Max 0 35A Max ON Resistance 2 Ohm N C or N O Voltage free relay contact V Max 45VAC current Max 0 35A Max ON Resistance 2 Ohm Diagnostic LED 1 red LED in receiver detector RX visible through lens 1 red LED in receiver ...

Reviews: