SYSTEM DESCRIPTION

 

 

The IR light curtain series WSE 81 PLUS and WSE EVO consist of a transmitter detector (TX) and a receiver detector 
(RX), they can be installed on the car door dynamically or statically on the doorsill. The detector system provides an IR 
light curtain with a crisscross beam pattern in the area of the car entrance. If any beam is blocked, the output is 
triggered and switches to reopen the doors again.   

 

 
 

 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WITTUR Austria GmbH

 

 

 

Sowitschstrasse 1 

A-3270 Scheibbs, Austria 

 

Tel +43 (0) 7482/42542-0 

Fax +43 (0) 7482/42542-232 

 

http://www.wittur.com

 

E-mail:  

[email protected]

 

 

 

Emphasis, translation and duplication in each form - also in excerpts - needs the written 

Authorization of the WITTUR Austria Ltd. 

We reserve the right to make alterations with respect to the specifications and figures in this manual. 

 

INSTALLATION 
The  systems  can  be  installed  either  on  the  moving 
doors  or  statically  in  a  position  on  the  end  of  the 
door sill. 
  
(a)

 

Dynamic Installation 

 
The system is mounted on the car doors using the 
dynamic fixing kit provided. 
 
1.  Position each detector on the car door. Check the 

detectors will be:  

· 

fitted approximately 5mm above the sill  

· 

aligned level and straight with each other  

2.  Screw the detectors to the door using the No 

6x16 self-drilling screws provided.  

3.  Secure the cables with the P-clips and No 

8x12mm self-tapping screws provided. Ensure 
the cables are securely held, there are no tight 
bends and they are no stressed or stretched as 
the doors move.  

 

(b)   Static Installation 
 

Please be aware of the maximum range of the 
systems when you are using static installation.  

 

 

 

Summary of Contents for WSE 81 PLUS Series

Page 1: ...xcerpts needs the written Authorization of the WITTUR Austria Ltd We reserve the right to make alterations with respect to the specifications and figures in this manual INSTALLATION The systems can be installed either on the moving doors or statically in a position on the end of the door sill a Dynamic Installation The system is mounted on the car doors using the dynamic fixing kit provided 1 Posi...

Page 2: ...eed 42V DC under any circumstances Peak ripple voltage should not exceed 42V and average voltage not exceeds 42V Sufficient power the supply must be capable of supplying at 100mA plus whatever current is needed to drive the door re open circuit on the lift Note if you have any doubts then you should use a WLS power supply IMPORTANT 1 Do not shorten cables by cutting them 2 Ensure that all cables a...

Page 3: ...00 852GB Version 1 Figure 3 Connection diagramm ECO MIDI SUPRA door controller If you are using the WLS power supply unit PLEASE USE TAPE FOR INSULATING THE GREEN WIRE TO AVOID A SHORT CIRCUIT IN THE WLS POWERSUPPLY UNIT X16 X15 Transmitter A Receiver B yellow red blue black black red green ...

Page 4: ...utput switches SW2 and SW3 to be set for detector configuration Relay Output Single pole changeover with hard silver contacts Maximum switching current 5 amps at 240V AC Housing High impact strength plastic box 130x100x45mm Connections Screw terminal blocks Audible Tone Fitted with a beeper and beeper ON OFF switch RXCableconnection WLS Switch Setting 0V 12V TRG LNK NPN N C Green Black Red Blue Ye...

Page 5: ...paque tape is removed When the 20 second timeout has completed the detector will switch back to normal mode so at the next power cycle it will not go into learning mode but it will remember those beams which need to be disabled To re enable learning mode the detector must be switched on with ALL the beams including previously disabled beams unobstructed To prevent the detector from having the lear...

Page 6: ...0mm Supply voltage 11 42 V DC continuous max 100 mA max peak 44V 11 42 V DC continuous max 100mA max peak 44V Output signal N C or N O Voltage free relay contact V Max 45VAC current Max 0 35A Max ON Resistance 2 Ohm N C or N O Voltage free relay contact V Max 45VAC current Max 0 35A Max ON Resistance 2 Ohm Diagnostic LED 1 red LED in receiver detector RX visible through lens 1 red LED in receiver ...

Reviews: