background image

Installation Instructions No. 9999-072-0

page 1

E2648_E.indd

Rel. 2 vom 02.03.2009

Carl Wittkopp GmbH

 

Sternbergstraße 5 · 42551 Velbert 

fon 02051- 95 66 0 · fax 02051 - 95 66 66 

http://www.cawi.com

Carl Wittkopp GmbH

CAWI Key-Operated Lock 2648 Optima

Then use four steel machine screws (M6 or the corresponding 

inch threads) to affix the key-operated lock so that it is perma

-

nently and securely attached. Prevent spontaneous loosening 

of these screws. It is advisable to insert a lock washer under 

each of the screw heads. In order to avoid malfunctions, the 

mounting screws may be tightened down only to a maximum 

torque of 10 Nm.

The bolt may not be subjected to stress or strain after 

installation.
The breakout segment in the base of the case may not 

be covered by any components.
Do not use lubricants or any other substances in the 

lock.

The key-operated lock requires no maintenance when used 

in a normal residential or office environment. It is advisable 

to have the lock inspected for security and proper function 

after about 10,000 operating cycles. Such inspections are to 

be carried out by personnel trained by cawi.
The  manufacturer’s  guarantee  will  be  invalidated  if  these 

installation instructions are not observed or if the lock’s case 

is opened by personnel not trained by cawi.

Follow these installation instructions when installing 

the lock. It should be noted that these installation in-

structions are a part of the VdS security certification; 

failure to follow these instructions will invalidate that 

certification. The lock is in all cases to be protected 

against tampering from the outside.

Installation Dimensions, CAWI Key-operated Lock

Item 2648 Optima, VdS Class 1

12  mm  stroke

25,3

12,5

41

9

66,5

55

61

49,2

24

7

22

23

15

Ø6,6

4

12

5,5

The aperture in the door of the safe may be a maximum
of 1,5 mm larger than the keyhole, all around its circumference.

breakout segment