LUC
+
125, 24 V, time-controlled
Revision: 01
1000088471
en-15
Information in
display
Meaning
See chapter
No display
Power supply not connected
OFF
Lubricator switched off
ON
Lubricator ready for operation
PRO
PRO menu
c1 ... 10
Adjustable setting of the number of cycles
c
01 ... 35
Adjustable setting of the emptying time
c
RUN
RUN menu
01 … 50
During the manually triggered active
run
command, the display shows the approximate
counterpressure in bar. In addition, the green
LED lights up.
FIL
FIL menu
01...50
During the manually triggered active
FIL
command, the display shows the approximate
counterpressure in bar. In addition, the green
LED lights up.
Clr
If the process is canceled during the
FIL
command,
Clr
is displayed
.
INF
INF menu
y01
Firmware version of the lubricator
r01
Firmware version of the lubricator
Pu0
Set control mode
t06
Currently set value of the emptying time
t
c02
Currently set value of the number of cycles
c
P50
Currently set maximum pressure
P
U12
Currently set value of the cartridge size
E1
Currently set error output
L1
Currently set empty cartridge message
F0
Currently set feedback signal
E1
Error
E1
(empty cartridge)
E2
Error
E2
(cartridge error / no cartridge fitted)
E3
Error
E3
(undervoltage)
E4/E5
Error
E4/E5
(fatal error)
E7
Error
E7
(overload)
01 … 50
After each cycle, the maximum applied counterpressure
during the cycle is displayed in bar.
Tbl - 9 Display messages