ELECTRICAL REQUIREMENTS
ELECTRICAL CODES & STANDARDS:
The warmer must be installed in
accordance with:
In the United States of America:
1.
State and Local Codes.
2.
National Electrical Code, ANSI/
NFPA-70 (latest edition.) Copies
may be obtained from: The
National Fire Protection
Association, Batterymarch Park,
Quincy, MA 02269.
In Canada:
1.
Local Codes.
2.
Canadian Electrical Code, CSA
C22.1 (latest edition.) Copies
may be obtained from: The
Canadian Standard Association,
178 Rexcale Blvd., Etobicoke,
Ontario, Canada M9W 1R3.
ELECTRICAL CONNECTIONS:
The warmer is factory wired for either
110/120 volt or 208/240 volt, single
phase operation. All 110/120 volt
warmers are equipped with a 8 foot cord
and NEMA 5-15 plug as standard
equipment. All 208/240 volt warmers
are equipped with a 8 foot cord and
NEMA 6-15 plug. Refer to wiring
diagrams in the back of this manual.
The cord and plug supplied is a suitable
durable cord with a molded three-prong
plug, and is provided with a proper
strain relief.
All warmers are
equipped with a three-prong plug. It
is imperative that this plug must be
connected into a properly grounded
three-prong receptacle. If the
receptacle is not the proper
grounding type, contact an
electrician.
DO NOT REMOVE THE
GROUNDING PRONG FROM THIS
PLUG.
Verify that the power source
matches the Serial Data Plate located
on the lower back corner of the
warmer and the plug configuration
before the connection is made.
(Fig. 1)
SERIAL DATA PLATE
Fig. 1
Summary of Contents for 200-1-CW
Page 14: ...DRAWER CHIP WARMERS F 41015 07 10 13 200 1 SL 200 1 SL BI...
Page 15: ...DRAWER CHIP WARMERS F 41015 07 10 14 200 2 CW 200 2R C 200 2R BI C 200 2R 200 2R BI...
Page 16: ...DRAWER CHIP WARMERS F 41015 07 10 15 200 2 SL 200 2 SL BI...
Page 17: ...DRAWER CHIP WARMERS F 41015 07 10 16 200 3R C 200 3R BI C 200 3R 200 3R BI...
Page 18: ...DRAWER CHIP WARMERS F 41015 07 10 17 200 4R C 200 4R BI C 200 4R 200 4R BI...