background image

HMD

 

SERIES

 

 

F-41142 (10-09) 

 

 

GENERAL 

 

INTRODUCTION 

 

Wittco 

HumidiHeat™ 

Holding & 

Transport Cabinets are produced with 
quality 

workmanship 

and 

material.  

Proper installation, usage, and 
maintenance of your cabinet will result 
in many years of satisfactory 
performance. 
 
It is suggested that you thoroughly read 
this entire manual and carefully follow all 
of the instructions provided. 
 
The  HMD  Series Holding & Transport 
Cabinets provide an efficient means of 
transporting and holding bulk prepared 
foods at proper serving temperatures. 
 

INSTALLATION 

 
Before installing, verify that the electrical 
service agrees with the specifications on 
the rating plate located on the lower 
back corner of the cabinet.  If the supply 
and equipment requirements do not 
agree, do not proceed with unpacking 
and installation.  Contact your Wittco 
Customer Service Department 
immediately.  

(Fig. 1) 

 

 

(Fig. 1) 

 

UNPACKING:

 

The Cabinet was inspected before 
leaving the factory.  The transportation 
company assumes full responsibility for 
safe delivery upon acceptance of the 
shipment.  Immediately after unpacking, 
check for possible shipping damage to 
the cabinet.   
 

If the cabinet is found to be damaged, 
save the packaging material and 
contact the carrier within 15 days of 
delivery.

 

 
Carefully unpack and place in a work 
accessible area as near the installation 
position as possible. 
 
1. 

Open the door and carefully 

 

remove any packaging materials 

 

and the retaining straps that hold 

 

the tray slides and tray slide 

 

upright side supports. 

 
2. 

Peel off vinyl protection film. 

 
3. 

Remove cardboard element 

 

cover protector from cabinet 

 

bottom. 

 
4. 

Remove adjustable tray slides 

 

from box. 

 
5. 

Remove the tray slide supports 

 

and install them in the cabinet. 

 
6. 

Hook the openings in the flat 

 

flange of the support over two 

 

vertical carriage bolts on the 

 

interior of the cabinet. 

 
7. 

Make sure all flanges on the four 

 

supports face the door opening. 

Summary of Contents for 1826-13-HMD

Page 1: ...tco com 2009 Wittco Foodservice Equipment F 41142 10 09 INSTALLATION OPERATION MANUAL HMD SERIES HumidiHeat HOLDING TRANSPORT CABINETS MODELS 1826 5 HMD 1826 13 HMD 1826 15 HMD For additional informat...

Page 2: ...MANUAL FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITYOF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MA...

Page 3: ...1 GENERAL 3 INTRODUCTION 3 INSTALLATION 3 ELECTRICAL REQUIREMENTS 4 LOCKOUT TAGOUT PROCEDURE 5 OPERATION 6 CONTROLS 6 OPERATING INSTRUCTIONS 6 SHUT DOWN 7 CLEANING 7 STAINLESS STEEL CARE 8 TROUBLESHOO...

Page 4: ...ment immediately Fig 1 Fig 1 UNPACKING The Cabinet was inspected before leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment Imm...

Page 5: ...ocal Codes 2 National Electrical Code ANSI NFPA 70 latest edition Copies may be obtained from The National Fire Protection Association 1Batterymarch Park Quincy MA 02269 www nfpa org In Canada 1 Local...

Page 6: ...E INJURY OR DEATH Always perform the LOCKOUT TAGOUT PROCEDURE before removing any sheet metal panels or attempting to service this equipment The Lockout Tagout Procedure is used to protect personnel w...

Page 7: ...rature range is from 80 F to 200 F OPERATING INSTRUCTIONS 1 Connect to proper electrical supply as indicated on data plate 2 Fill water into Water Reservoir Reservoir holds approx 1 gallon or 3 78 lit...

Page 8: ...the Temperature Control Knob counterclockwise to the OFF position 2 Turn the Humidity Control Knob counterclockwise to the OFF position 3 Unplug unit from the electrical power supply Always UNPLUG EL...

Page 9: ...sed or chloride containing cleaning solutions which will break down the protective film 4 Never rub in a circular motion Always rub gently in the direction of the steel grain 5 Never leave any food pr...

Page 10: ...ks moisture Damaged door gasket or door requires adjustment Contact Authorized Service Provider Door not properly shut Shut door Door gasket damaged Contact Authorized Service Provider Heating element...

Page 11: ...N mm DEPTH IN mm WIDTH IN mm SHIPPING WT Lb kg VOLTS WATTS AMPS 1826 5 HMD 32 375 34 25 25 125 170 77kg 120 1200 10 1826 13 HMD 59 375 1700mm 34 25 857mm 25 125 724mm 340 154kg 120 1200 10 1826 15 HMD...

Page 12: ...HMD SERIES F 41142 10 09 11 WIRING DIAGRAM...

Reviews: