Witt Sensoric LIGI-07 Original Operating Instructions Download Page 21

21

EG-Konformitätserklärung
EC Declaration of conformity

Wir als Hersteller und Bevollmächtigter für die 
Zusammenstellung der technischen Unterlagen:

We, the manufacturer and authorized represen-
tative to compile the technical documents:

Witt Sensoric GmbH, Ernst-Lau-Str. 12, 12489 Berlin, Germany

erklären hiermit in alleiniger Verantwortung, 
dass folgende Produkte:

hereby declare under our sole responsibility, that
following products:

Lichtgitter LIGI mit den folgenden 
Bezeichnungen

Light curtain LIGI with the following 
designation

Name

Geh.

Ausg.

Test

Strahl-

typ

Kanal-
anzahl

Schutzfeld-

höhe

Torfunktion

mit / ohne

Kabel

Sonder-

ausf.

LIGI

01
07
08
10

OSE

T00

A
C

F
K

11..70

495..2520mm

F00
F01
F04
F05
F06
F07
F08
F09
F10

C00
C01
C02
C03

Sxxx

P01
P02
P03

N01
N02
N03

R01
R02
R03

T01
T02
T03
T04
T05

allen einschlägigen Anforderungen der 
folgenden EG-Richtlinien entsprechen:

fulfill all relevant requirements of the following 
EC directives:

RoHS-Richtlinie 2011/65/EU
EMV-Richtlinie 2014/30/EU
Maschinenrichtlinie 2006/42/EG

RoHS Directive 2011/65/EU
EMC Directive 2014/30/EU
Machinery Directive 2006/42/EC

Folgende Normen oder Teile dieser Normen 
wurden angewendet:

Following standards or parts of these were 
applied:

EN 12978

Schutzeinrichtungen für kraftbetätigte Türen und 
Tore

Safety devices for power operated doors and 
gates

EN ISO 13849
Cat. 2, PL-d

Sicherheit von Maschinen – Sicherheitsbezogene 
Teile von Steuerungen

Safety of machinery - Safety-related parts of 
control systems

IEC 61496-2
Typ 2

Sicherheit von Maschinen – Berührungslos 
wirkende Schutzeinrichtungen 

Safety of machinery – Electro-sensitive protective 
equipment 

EN 61000-6-3

Elektromagnetische Verträglichkeit (EMV) – Teil 
6-3: Fachgrundnormen – Störaussendung für 
Wohnbereich, Geschäfts- und Gewerbebereiche 
sowie Kleinbetriebe

Electromagnetic compatibility (EMC) – Part 6-3: 
Generic standards – Emission standard for 
residential, commercial and light-industrial 
environments

EN 61000-6-2

Elektromagnetische Verträglichkeit (EMV) – Teil 
6-2: Fachgrundnormen – Störfestigkeit für 
Industriebereiche

Electromagnetic compatibility (EMC) - Part 6-2: 
Generic standards – Immunity standard for 
industrial environments

Berlin, 06.03.2018

Jörg Brech

Geschäftsführer / Managing Director

Summary of Contents for LIGI-07

Page 1: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 1 Sensoric Original operating instructions Safety light curtain LIGI 07...

Page 2: ...05 open is normal operation test low or high Beam geometry A continuous high detection capability C standard compliant detection capability Active light beams Active detection zone in mm F Function 00...

Page 3: ...sing barriers barriers that are used solely for vehicle traffic and dangerous machines that are not doors During mounting installation and commissioning it must be ensured that the pho to switch syste...

Page 4: ...sured that the door control system checks the safety light curtain versions with a test input once per door cycle To do so the control system must trigger the test input on the transmitter for at leas...

Page 5: ...If the test input of the light curtain is activated for longer than 15s the light curtain switches into alignment mode The signal reserve can be optimised in alignment mode by alternately rotating the...

Page 6: ...d the door can then only be operated in dead man mode Electrical connection Operating mode The connections are made depending on the version according to the supplied circuit diagram Important note Th...

Page 7: ...The more the level increases the faster the flash frequency of the red LED will be When the maximum flash frequency is reached the light curtain is optimally aligned and can be fastened in place For...

Page 8: ...flashes 2x long pause Check output cable overload wrongly con nected cable defective output on light curtain defective Error in sync cable Yellow LED flashes 3x long pause Check sync cable white may...

Page 9: ...y If the previous step has been carried out correctly the green LED on the receiver will be continuously on and the red LED will flash The reference values will then be pro grammed It is essential to...

Page 10: ...n the transmitter and receiver is connected with 10 30 V DC for longer than 15s and less than 25s all the saved reference values from the programming process will be actively deleted i e the factory s...

Page 11: ...nge of 0mm to 300mm above the ground 2 A test object with an edge length of 200mm must be continuously detected over a range of 0mm to 2500mm above the ground The test bodies should be moved from bott...

Page 12: ...t be replaced Furthermore please check detection ability on a regular basis as per manual page 11 If light curtains are replaced they must only be replaced by identical light curtains or by other safe...

Page 13: ...50Hz PNP output High level NPN output Low level solid state relay SSR low resistance Aperture angle Approx 5 Detection capability 0 to 300mm detection object 50mm version C 300 to 2500mm detection obj...

Page 14: ...afety 100klux Housing material Aluminium profile fully filled with 2K epoxy resin Connection Pig tail M8 plug 6 pin L 130mm Degree of protection IP67 as per EN 60529 Operating temperature 20 to 60 C S...

Page 15: ...the output P01 after max 100ms switch from low to high level N01 after max 100ms switch from high to low level OSE This version is not tested solid state relay SSR after max 100ms change from high re...

Page 16: ...ung zwischen Empf nger und Sender Test aktiv bei 10 30VDC Transmitter Receiver 10 30VDC 0V GND Test Alignment input not assigned not assigned Sync 10 30VDC 0V GND SSR output SSR output not assigned Sy...

Page 17: ...High level or switch closed T03 Test Low level or switch closed T04 Test High level or switch open 0V GND 10 30V 10 30V test high level 0V GND test low level open standard operation Test input Test i...

Page 18: ...45 45 45 45 45 45 45 45 45 45 45 45 45 7 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 7 45 2363 indicator LED 2363 indicator LED 2430 aktive detection zone 5...

Page 19: ...Version A Version C 5 45 45 45 45 45 45 45 45 45 45 45 118 45 45 45 45 45 45 45 45 45 45 45 45 45 45 5 45 45 45 45 45 45 45 45 45 45 45 118 45 45 45 45 45 45 45 45 45 45 45 45 45 45 5 45 45 45 45 45 4...

Page 20: ...Volume mm Anzeige LED 7 22 5 22 5 2518 24 24 45 2388 aktive Schutzfeldh he 55Kan le 12 4 10 45 A A 1 5 1 G 1 5 1 H 1 5 1 A B C LIGI 07 55 Kan le Gez Kontr Datum Name 10 03 2017 10 03 2017 pollak Brech...

Page 21: ...nie 2006 42 EG RoHS Directive 2011 65 EU EMC Directive 2014 30 EU Machinery Directive 2006 42 EC Folgende Normen oder Teile dieser Normen wurden angewendet Following standards or parts of these were a...

Page 22: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 22 Sensoric Notes...

Page 23: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 23 Sensoric...

Page 24: ...www witt sensoric de 24 Sensoric Sensoric Witt Sensoric GmbH Ernst Lau Stra e 12 12489 Berlin Germany Tel 49 0 30 75 44 94 120 Fax 49 0 30 75 44 94 123 sales witt sensoric de www witt sensoric de Wit...

Reviews: