7
Bar-graph meters
:
RF field strengths (both “
A
” and “
B
” antennas at the same time )
AF output level (-20 ÷ +12 dBu).
TX battery lifetime, 5 steps:
100%
,
75%
,
50%
,
25%, 12%
(the last Led blinks ).
Led indications
:
diversity switching (“
A
” / “
B
” antenna)
AF output-line is active (
AF ON
)
matching sub-carrier is present (
P.TONE
)
channel Group 1 selected (
#1
)
tone-squelch function is on (
T.SQL
)
receiver on.
Powering
:
10.5 ÷ 16 Vdc / 4 W (typ.: 350 mA @ 12 Vdc), negative ground
mains 100 ÷ 240 Vac, by means of separated PSP910-X4 “mains-plug” power
supply.
Size
:
240,99 x 225,2 x 43,6 mm (WxDxH)
Weight
:
1.7 Kg approx.
Note [1]:
RMS value, unweighted, 22 Hz / 22 kHz, and referred to the peak deviation.