WisyCom CSI16T User Manual Download Page 4

Rev.03

 

 

CSI16T  User Manual

 

 

 

3

 

 

 

 

According to the RF power level and the compensation, led can be green, blue or red. 

INPUT led: 

■ 

GREEN:

 

if RF level of input port is > 8dBm 

and

 RF level of the related output port is >8dBm 

■ 

BLUE:

 

if external compensation is activated on input port  

 

OUTPUT led: 

■ 

GREEN:

 

if RF level of output port is > 8dBm  

■ 

BLUE:

 

if extra compensation ❷ is activated and combiner mode is set to 16->1  

■ 

RED flashing:

 

if there is a falty on the combiner path 

NOTE

: External compensation doesn’t work if between MTK952N and CSI16T/CSA121T there 

are devices which keep out the DC. 

example: 

combiner mode: 4x4->1  

on the first 4 input ports and on the  output port “A” there are 
an RF level >8dBm, no external compensation is activated 

 

example: 

combiner mode: 2x8->1  

on the first 8 input ports and on the  output port “A” 
there are an RF level >8dBm, external compensation is 
activated in all the 8 input ports 

 

❹ POWER indication 

Redundant power supply AC and DC can be used. Related led can be  

■ 

GREEN:

 

if power supply is present 

■ 

BLUE:

 

if power supply is in use* 

*if both DC and AC power supply are present, the combiner uses the one with higher voltage 

 

 

NOTE

CSI16T works without power supply!

 It works according to the latest set combiner 

mode.  

 

Summary of Contents for CSI16T

Page 1: ...SN ________________ Rev 03 Date 02 August 2017 CSI16T User Manual Smart Passive Wideband Combiner...

Page 2: ...ation Do not lose this manual Do not use this apparatus under the rain or near the water Do not install the apparatus near heaters or in hot environments do not use outside the operating temperature r...

Page 3: ...selector set to on I activates the extra compensation only if combiner mode is set to 16 1 configuration connected to another combiner CSA121T it is able to recover up to 15dB of loss see example 3 LE...

Page 4: ...52N and CSI16T CSA121T there are devices which keep out the DC example combiner mode 4x4 1 on the first 4 input ports and on the output port A there are an RF level 8dBm no external compensation is ac...

Page 5: ...8 1 configuration with high power transmitters Country power limit 50mW Enabling external compensation on MTK952Ns the transmitters raise power of 9dB in order to limit to 50mW the maximum power at th...

Page 6: ...ut of CSA121T Both CSI16Ts are configured at 16 1 with external combiner enabled Example4 Ports unused and termination To avoid wrong indications in the input led it is necessary to terminate at 50 AL...

Page 7: ...r each input connector Combiner loss approx 6 dB for 4x 4 1 approx 9 dB for 2x 8 1 approx 12dB for 16 1 Port separation 30 dB typical Power supply AC connector 90 264Vac 47 63Hz fuse protected T2A 50W...

Page 8: ...Wireless System Communications Via Spin 156 I 36060 Romano d Ezzelino Italy Tel 39 0424 382605 Fax 39 0424 382733 www wisycom com e mail sales wisycom com...

Reviews: