CSI16T  User Manual

  Rev.03

 

 

 

 

2

 

R

EAR AND 

F

RONT 

P

ANEL

 

 

 

 

WARNING

:  

ALL THE UNUSED PORTS related to the selected combination SHOULD TO BE TERMINATED 

AT 50Ω 

(

see example 4

). 

 

 

 

 

 

 

 

 

 

 

 

 

 

❶ Combiner mode 

Three position selector allows to select one of the following combiner mode 

 

4x4->1 

 

16->1 

 

2x8->1 

❷ External combiner 

External combiner selector set to on (I) activates the extra compensation (only if combiner 
mode is set to [16:1] configuration): connected to another combiner CSA121T, it is able to 
recover up to 15dB of loss (

see example 3

). 

❸ LED indication 

Thanks to an RF meter present in the input/output ports, each port is able to detect the 
presence of RF level more than 8dBm. Moreover, a special circuit is able to detect if the 
external compensation is activated or not from the transmitter side. 

❶ 

❷ 

❸ 

❹ 

input C 

input D 

input A 

input B 

output 

DC - AC 

Summary of Contents for CSI16T

Page 1: ...SN ________________ Rev 03 Date 02 August 2017 CSI16T User Manual Smart Passive Wideband Combiner...

Page 2: ...ation Do not lose this manual Do not use this apparatus under the rain or near the water Do not install the apparatus near heaters or in hot environments do not use outside the operating temperature r...

Page 3: ...selector set to on I activates the extra compensation only if combiner mode is set to 16 1 configuration connected to another combiner CSA121T it is able to recover up to 15dB of loss see example 3 LE...

Page 4: ...52N and CSI16T CSA121T there are devices which keep out the DC example combiner mode 4x4 1 on the first 4 input ports and on the output port A there are an RF level 8dBm no external compensation is ac...

Page 5: ...8 1 configuration with high power transmitters Country power limit 50mW Enabling external compensation on MTK952Ns the transmitters raise power of 9dB in order to limit to 50mW the maximum power at th...

Page 6: ...ut of CSA121T Both CSI16Ts are configured at 16 1 with external combiner enabled Example4 Ports unused and termination To avoid wrong indications in the input led it is necessary to terminate at 50 AL...

Page 7: ...r each input connector Combiner loss approx 6 dB for 4x 4 1 approx 9 dB for 2x 8 1 approx 12dB for 16 1 Port separation 30 dB typical Power supply AC connector 90 264Vac 47 63Hz fuse protected T2A 50W...

Page 8: ...Wireless System Communications Via Spin 156 I 36060 Romano d Ezzelino Italy Tel 39 0424 382605 Fax 39 0424 382733 www wisycom com e mail sales wisycom com...

Reviews: