- 19 -
Handset OH 41 (Accessory)
Note: After programming
remove the handset from the
connector.
Left
Right
Down
Up
W I S I
HW V 1 . 0 0
H E A D E N D SW V 1 . 0 0
Standby
Mains connected to basic unit and the mode
„Initializing the modules“has finished (see next page).
Plug the handset into the socket on the basic unit.
Press the
►
key to enter the module menu and system menu.
Modul menu
Module 1 OH77
Parameter menu
Module 2 OH85
DiSEqC
Sat-Freq
Parameter sub-menu
1894
Module 14 OH88H
Modul menu
Press the
►
key
▲▼
keys — Select module 1-14
►
key
— Move to parameter menu
◄
key
— Back.
Parameter menu
▲▼
keys — Select parameter
►
key
— Move to parameter sub-menu
◄
key
— Back
Parameter sub-menu
◄►
keys — Select the digit to be changed
Cursor blinks below the digit, e.g. 1894
If the permissible range is exceeded, the unit
returns to the parameter menu
▲▼
keys — Change the value, e.g. change 1894 to 1834
-
Saving data:
Data are saved automatically after leaving the para-
meter menu, or 60 seconds after the last entry.
- Connect OH 50 A to mains power
- Connect the handset OH 41
- Modules are scanned in the background (can take up to 1 min!)
The description of the menu structures can be found in the related manual of the module.
Initializing the modules