background image

INS_TE(C,U)-FX   

08/12/19

   PAGE 5

INSTALLATION AND OPERATION MANUAL 

TE(C,U)-F SERIES

CH4 

EXT DISTANCE

CH12 

EXT DISTANCE

CH5 ETHERNET

CH13 ETHERNET

CH8 

EXT DISTANCE

CH16 

EXT DISTANCE

CH1 ETHERNET

CH9 ETHERNET

CH3 

EXT DISTANCE

CH11 

EXT DISTANCE

CH6 ETHERNET

CH14 ETHERNET

CH7 

EXT DISTANCE

CH15 

EXT DISTANCE

CH2 ETHERNET

CH10 ETHERNET

CH2 

EXT DISTANCE

CH10 

EXT DISTANCE

CH7 ETHERNET

CH15 ETHERNET

CH6 

EXT DISTANCE

CH14 

EXT DISTANCE

CH3 ETHERNET

CH11 ETHERNET

CH1 EXT DISTANCE

CH9 EXT DISTANCE

CH8 ETHERNET

CH16 ETHERNET

CH5 

EXT DISTANCE

CH13 

EXT DISTANCE

CH4 ETHERNET

CH12 ETHERNET

FIGURE 7 – TEC-F16 MULTICHANNEL RACK COAX UNITS

Data rate DIP switch

See Installation 

Instructions, Step 1

Data rate DIP switch

See Installation 

Instructions, Step 1

Data rate DIP switch

See Installation 

Instructions, Step 1

Data rate DIP switch

See Installation 

Instructions, Step 1

Operating Power:  9 to 15 VDC
Power Consumption: 20W

Black (DC–)
Black w/ White Stripe (DC+)

Summary of Contents for TEC-F Series

Page 1: ...nits operate from local power These units provide the ultimate flexibility for extending a powered device PD over long distance copper DIP switches are provided for user selection of local or remote 10 or 100Mbps and 1 pair or 4 pair UTP settings The TE C U F16 are 1RU rack mountable units The TE C U F04 units are interchangeable between stand alone or card mount configurations or may be DIN rail ...

Page 2: ...OR 9 to 36 VDC OR 24 VAC Power Consumption 1 5 W Black AC or DC Black w White Stripe AC or DC Black AC or DC Black w White Stripe AC or DC Local Remote push button See Installation Instructions Step 3 Local Remote DIP switch 10 100 data rate DIP switch Wire pair DIP switch 10 100 data rate DIP switch Local Remote DIP switch UP DOWN DOWN UP Switch UP DOWN Local Remote Remote Local 10 100 10 Mbps 10...

Page 3: ...AX UNIT CH1 EXT DISTANCE CH1 ETHERNET CH2 EXT DISTANCE CH2 ETHERNET CH3 EXT DISTANCE CH3 ETHERNET CH4 EXT DISTANCE CH4 ETHERNET Operating Power 9 to 15 VDC Power Consumption 5W Black DC Black w White Stripe DC Local Remote push button See Installation Instructions Step 3 10 100 data rate DIP switch See Installation Instructions Step 1 Local Remote DIP switch See Installation Instructions Step 3 ...

Page 4: ...UNT UTP UNITS CH1 EXT DISTANCE CH1 ETHERNET CH2 EXT DISTANCE CH2 ETHERNET CH3 EXT DISTANCE CH3 ETHERNET CH4 EXT DISTANCE CH4 ETHERNET Operating Power 9 to 15 VDC Power Consumption 5W Black DC Black w White Stripe DC Local Remote DIP switch See Installation Instructions Step 3 Wire pair DIP switch See Installation Instructions Step 2 Data rate DIP switch See Installation Instructions Step 1 ...

Page 5: ...ETHERNET CH15 ETHERNET CH6 EXT DISTANCE CH14 EXT DISTANCE CH3 ETHERNET CH11 ETHERNET CH1 EXT DISTANCE CH9 EXT DISTANCE CH8 ETHERNET CH16 ETHERNET CH5 EXT DISTANCE CH13 EXT DISTANCE CH4 ETHERNET CH12 ETHERNET FIGURE 7 TEC F16 MULTICHANNEL RACK COAX UNITS Data rate DIP switch See Installation Instructions Step 1 Data rate DIP switch See Installation Instructions Step 1 Data rate DIP switch See Insta...

Page 6: ...CE CH8 ETHERNET CH16 ETHERNET CH5 EXT DISTANCE CH13 EXT DISTANCE CH4 ETHERNET CH12 ETHERNET FIGURE 8 TEU F16 MULTICHANNEL RACK UTP UNITS Data rate DIP switch See Installation Instructions Step 1 Data rate DIP switch See Installation Instructions Step 1 Data rate DIP switch See Installation Instructions Step 1 Data rate DIP switch See Installation Instructions Step 1 Wire pair DIP switch See Instal...

Page 7: ...lustrated Please contact Technical Support to discuss your specific requirements PoE Ethernet Switch or Midspan Local Remote TE C U F01 TE C U F01 PoE Camera Ethernet Switch Local Remote Power Power Power TE C U F01 TE C U F01 IP Camera Ethernet Switch Local Remote TE C U F04 TE C U F16 TE C U F01 TE C U F01 TE C U F01 TE C U F01 Power IP Camera Power Power IP Camera Power Power IP Camera Power Po...

Page 8: ...e dip switch The TE C U F16 units are preconfigured as Local devices 4 CONNECT EXTENDED WIRING Connect Extended Distance Port to field wiring 5 CONNECT NETWORK WIRING Using CAT5 5e cabling connect Local unit to network and Remote unit to camera 6 CONNECT POWER Connect power to unit per the following table Power Connections per Use Case Unit Local Power Pass Through PoE TE C U F01 9 to 36 VDC or 18...

Page 9: ... IEEE 802 3af rated PoE Source switch is set properly and the extended distance is within specifications see Table Approximate Maximum Extended Distances Units not reaching estimated max distances over COAX or CAT5 UTP Check extended distance cable and connections Try connection on a short cable to eliminate possibility of faulty cabling Check that the extended distance wire is connected to Extend...

Page 10: ...ons are for a standard module FIGURE C Dimensions are for a 19 Rack Unit 8 38cm 3 3in 2 7cm 1 06in 4 19cm 1 65in 0 8cm 0 31in 0 4cm 0 16in 0 62cm 0 24in 6 37cm 2 50in 13 2cm 5 2in 11 9cm 4 7in 15cm 5 9in 7 5cm 2 9in 0 63cm 0 25in 2 75cm 1 1in 44 45cm 17 50in 48 26cm 19 0in 15 44cm 6 08in 1 9cm 0 75in 4 37cm 1 72in 1 9cm 0 75in PRODUCT DIMENSIONS ...

Page 11: ...ir flow required for safe operation of the equipment is not compromised SBP C14 SBP C03 CARD CAGE RACKS CAUTION Although the units are hot swappable and may be installed without turning power off to the rack Hanwha recommends that the power supply be turned off and that the rack power supply is disconnected from any power source Note Remove electrical connector before installing in card cage rack ...

Reviews: