33
5.
Please installation again for the laser software and texting again
6.
Please formatting the computer system and installation the software again and texting again.
7.
Please check the main board gorge is it damage ,if its please repair or change a new one .
7.13 SOFTWARE ERROR ALERT INTERFACE.
The operation panel can real-time display the alert interface ,which cause by various improper operation or external
disturbance signal. According to the information which display on the panel , it is easy for the user to correct the
wrong operation, and exclude the external disturbance signal .
1. Soft limit stops
When found this kind of error , it show that the work scope data ,which input into the computer is bigger than the real
worktable .
Solution :
Remove the laser head, and make it in the scope of the worktable. Another way is that conceal the “immediately
output order “reset the proper data again, and then download the data .
2. Hard limit stops
When the user operate the machine while does not make the laser head back to the original point .It is easy cause that
the processing area is bigger than the real worktable and when the laser head bump into the “size control signal “ the
movement have to cease .
On the other hand, when the machine in a complex environment which have a lot of interference signal , it will also
display this kind of information .
Solution :
Remove the laser head ,and make the processing graphic data in the scope of the worktable.
When we find the alert information while the laser head does not bump into the “size control signal “ so we can
sure ,it is caused by the external disturbance signal . When we meet this kind of situation, please check the ground
cable
3. Lack of memory space alarming
Reasons:
a)The number of download files is more than the total number of Memory device—32
b) The download files is too big and exceed the Memory device
Solving Method:
Make sure that the download files not exceed the total memory of Memory device. Remove the files that we
don’t