background image

1.  INTRODUCTION
    
     The Venturi Tube manufactured by WISE CONTROL INC is a product 
   manufactured in compliance with the specifications of clients. This product 
   should be stored in the proper place. And it should surely comply with  
   requirements such as various kinds of document, report, and instruction manual 
   in order to maintain the optimum status of use during the period that it is used.

2.  USE

     It is a device to be installed in the piping or pipeline through which fluid passes, 
   and to produce differential pressure before and after this.  

3.  WARRANTY

     In case of arbitrary modification, change, and repair, and damage caused because of 
   not complying with the provisions of instruction manual when the product is used,    
   the manufacturer doesn't take responsibility, and the warranty of product is
   also terminated. 

INSTALLATION & OPERATION MANUAL

DOC.NO. :  C-QIM-2731-F04

REV.0

WISE CONTROL

PAGE : 3/5

Summary of Contents for VENTURI TUBE

Page 1: ...19F 181 Gasan digital 1 ro Geumcheon gu Seoul Republic of Korea Tel 82 2 300 2300 Fax 82 2 300 2301 ITEM VENTURI TUBE INSTALLATION OPERATION MANUAL DOC NO C QIM 2731 F04 REV 0 WISE CONTROL PAGE 1 5 ...

Page 2: ...ES BEFORE THE INSTALLATION 5 MATTERS THAT REQUIRE ATTENTION IN THE INSTALLATION 6 MAINTENANCE OF THE VENTURI TUBE 7 STORAGE METHOD AND RETURN PACKAGING OF PRODUCT CONTENTS INSTALLATION OPERATION MANUAL DOC NO C QIM 2731 F04 REV 0 WISE CONTROL PAGE 2 5 ...

Page 3: ...tus of use during the period that it is used 2 USE It is a device to be installed in the piping or pipeline through which fluid passes and to produce differential pressure before and after this 3 WARRANTY In case of arbitrary modification change and repair and damage caused because of not complying with the provisions of instruction manual when the product is used the manufacturer doesn t take res...

Page 4: ...points are aligned as per the manufacturer s or the contractor s drawing 4 Ensure that all weld outlines are even Take care to ensure that any protrusion inside the pipe is kept to an absolute minimum For a flanged unit any protrusion inside the pipe must be groud off and swept clean CAUTION 5 The tapping and any associated impulse piping must be clear prior to putting into service Check that ther...

Page 5: ...he product shall not to be exposed to moisture dust and other pollutants in transit 5 The product shall be so packaged that it is not exposed to shock in transit according to the delay of installation can be claimed against the transport company 7 The relative humidity and temperature in storage or transit should be applied under condition Temperature 20 10 Relative Humidity Max 60 6 The product d...

Reviews: