background image

 

           

   

   

  

 

Wise Telecommunications Industry 

                                                                        

11 

 

 

Maximum  Hold:

  Function  responsible  for  holding  the  highest  values  on  the 

screen. Use the  

,  

 or 

  to change the option for YES or NO. 

 

Minimum  Hold:

  Function  responsible  for  holding  the  smaller  values  on  the 

screen. Use the  

,  

 or 

  to change the option for YES or NO. 

 

Pass/Fail  Configuration:

  Function  responsible  for  setting  up  the  value  of  the 

matter failed. Use the 

,  

 or 

 to change the value of the channel 

and the alphanumeric keys to enter the new value. 

 

4. Tests 
4.1 Channel Test 

Channel  Test  screen  always  starts  showing  the  measures  of  the  last  channel 

selected. To change the channel just enter the channel number with the number keys, or 
use the key 

 and  

 or press 

 to enter the channel screen. This screen use 

the directional keys

 

 

 and  

  to change the digits and

 

 

 and 

   to change 

the cursor position. 

Press 

 to confirm the selected channel. 

The  channels  test  there  are  two  types  of  channels:  digital  and  analog. Different 

parameters will appear in the case of an analogue or digital channel to be chosen. You 
can  also  choose  to  show  the  measures  or  information  about  the  selected  channel, 
press

 

 

 to change the preview type. 

 

 

(a)

 

Measures of the                      (b) Analog channel                            (c) Channel choice. 
analog channel.                              Information. 
         

Figure 4.1: Test channels.

 

 

Analog channel

 

The channel test captures the signal and calculates the difference between the audio 

and video carriers. On this screen, you can choose the channel. In addition, the following 
parameters can be viewed:

 

         

Type

 

Analogue or Digital.

 

         

Channel

 

Channel number.

 

         

Name

 

Name of the channel.

 

         

Video Freq.

 

Summary of Contents for TSW500CATV

Page 1: ...Wise Telecommunications Industry 1 Operation Manual TSW500CATV Version 1 Revision 0 November 2017 ...

Page 2: ...under constant development some characteristics may not be included in the manuals please check the following manual version when it is published Any contribution or criticism that can improve such product or manual will be welcome by the company team If this manual contents are not corresponding to the equipment version or its operation please contact the company support Telefone fax 61 3486 9100...

Page 3: ... 2 2 Battery 6 3 Equipment Initial Operation 7 3 1 Setting the Equipment 7 3 1 1 System Configuration 7 3 1 2 Date time Configuration 8 3 1 3 Channel Configuration 8 3 1 4 Line Up Update 9 3 1 5 Ingress Configuration 10 4 Tests 11 4 1 Channel Test 11 4 2 Frequency Test 14 4 3 Tilt 14 4 4 Full Scan 15 4 5 Ingress Test 16 4 6 Voltmeter 16 5 Software Update 17 ...

Page 4: ...d and a liquid crystal display besides it has an LED to indicate the battery charge The equipment is powered by an internal battery pack must be charged using the original source The following tests may be done Channel test Frequency test Tilt Full Scan Ingress Test Voltmeter 1 2 Technical Specifications Frequency Frequency Range 5 MHz to 1 GHz Channel Level measurement range 48 to1000 MHz Level t...

Page 5: ... e 9 Voltmeter Voltage 1 Vdc until 100 Vdc 2 Characteristics 2 1 Keyboard Figure 2 1 TSW500CATV Keyboard The TSW500CATV keyboard has a key diversity to facilitate your operation Power Button Go to the main menu Function of these keys dependent on the screen displayed The label displayed in the lower line right above the keys defines these functions Begins the test select the desired test mode Retu...

Page 6: ...g charged If the LED turns green means that the battery has achieved its maximum charge capacity The TSW500CATV then remains powered by the loader so that after disconnection or power failure the batteries will be with full load Charge time from the battery fully discharged is 4 hours and it lasts about 6 hours of continuous use If the battery is not charged up to its maximum capacity the TSW500CA...

Page 7: ...f testing that will be done Channel test Frequency test Tilt Full Scan Ingress Test and Voltmeter Figure 3 1 TSW500CATV Menu The choice is made using the move keys and To start the desired test press 3 1 Setting the equipment Press the key to enter in the settings of TSW500CATV use the keys and to choose the options Figure 3 2 Setup Options screen 3 1 1 System Configuration Figure 3 3 System Setup...

Page 8: ...ately 10 seconds with an error of 0 1 dBmV Language The options are EN English and PT Portuguese 3 1 2 Date Time Configuration Figure 3 4 setting the date and time Clock Change the clock to 24 hour format Use the directional keys to change the digits and press to confirm Date Changes the date day and month Use the directional keys to change the digits and press to confirm Year Changes the year Use...

Page 9: ...the character type A maximum of 8 characters is allowed Press to confirm and to cancel the editing at any time 3 1 4 Line Up Update IMPORTANT Never connect the USB cable and the coax at the same time it can generate from malfunctions until destruction of equipment There is in the TSW500CATV the option to create and update the line up of channels through the software can be downloaded on the websit...

Page 10: ... from multiple equipment a new screen will appear asking to what equipment you want to open save There is the ALL option in the option Save on equipment to upgrade equipment at the same time Remembering that the line up file is a csv file comma delimited file which can be created in excel or in note block of the following modes a CSV file in excel b CSV files in Notepad Figure 3 8 CSV file creatio...

Page 11: ...the key and or press to enter the channel screen This screen use the directional keys and to change the digits and and to change the cursor position Press to confirm the selected channel The channels test there are two types of channels digital and analog Different parameters will appear in the case of an analogue or digital channel to be chosen You can also choose to show the measures or informat...

Page 12: ...graphic on the screen So the spectrum is fully traversed press to use a marker to show the power in the marker frequency use the key keys and to move the marker Figure 4 2 Spectrum screen with marker Canal Digital The screen is the main for digital channels Figure 4 3 QAM constellation screen Within the constellation screen press or to change the channel to show the spectrum of the channel and to ...

Page 13: ...can be viewed in sequence the channel number name and type frequency bandwidth modulation standard used and modulation rate measured in symbols per second FEC LOCK a Level of the digital channel b Digital channel information Figure 4 5 Digital channel Test When in lock is with Forward Error Correction enabled PS LOCK When in lock is with Packet Synchronization enabled BERPRE Bit error rate before ...

Page 14: ...ncy press to select 4 3 Tilt The Tilt is a function that calculates a line between the largest and the smallest frequency of channels chosen On the following screen keys and are used to mark and unmark the chosen channels navigation between them is made using the keys and It is necessary a minimum of 2 channels to start the calculation and you can choose a maximum of 15 channels To start press a T...

Page 15: ...nels and plots on a graph of power and frequency on the screen The colors differentiate the types of channels red to digital channels green and blue to analogue channels green for audio and blue for video or orange and black black for video and orange for audio for the case of channels with a difference between the audio and video power greater than 17dBmV or less than 13dBmV When finished it is p...

Page 16: ... is 5 to 45 MHz The directional keys and change the threshold shown in the lower left side along with the test results The change of threshold restarts scanning The directional keys and move the cursor The value is shown on the lower right side The button restarts the test 4 6 Voltmeter Figure 4 11 Voltmeter The voltmeter is used to measure DC voltage on the cable for field testing ...

Page 17: ...ommunications industry www wi com br After installing the UPW follow these steps to update the equipment Turn on the equipment by holding and pressing The following screen will appear Figure 5 1 Equipment update screen Connect the equipment to a PC that is being used for the upgrade Start the connection in UPW and click OK to continue The message Operation Completed will appear on the screen indic...

Reviews: