PRoGRAMMInG
Parameter
Value
Description
“A”
Plunger Mode
1
Single plunger (Start/Stop only)
2*
Dual plunger (Start/Stop/Throttle)
“b”
Throttle Mode (Only if A is set to 2)
1*
Throttle relays latch ON and OFF (maintained)
2
Throttle relays are momentary (on-demand)
3
T1 latches ON, T2 momentary, STOP turns both OFF
4
T1 & T2 latch ON, T2 OFF, STOP turns both OFF
5†
Timed operation (see “E”)
6
T1 latches ON, T1 OFF & T2 latches ON, T1 & T2 OFF
7
T1 momentary ON, T2 momentary ON, repeat
8
No throttle mode
9†
As soon as MASTER Power is applied:
T1 latches ON, T2 momentary, STOP turns both OFF
A†
As soon as MASTER Power is applied:
T1 latches ON, T2 latches ON/OFF with Throttle input signal,
STOP turns both OFF
“C”
AUx (Emergency Power) Mode
1*
AUx (Emergency Power) from the J1 Pin 4 input (THROTTLE)
2
AUx (Emergency Power) from the J1 Pin 5 input (START/STOP)
3
RESERVED
4
AUx (Emergency Power) from J1 Pin 2 (AUx TRIG)
5
Auto Stop on Loss of Pressure Mode (see appendix V)
“D”
AUx (Emergency Power Time)
0-9, 3*
Time delay for Emergency Power relay actuation,
“E”
Throttle Mode Timer
0-9, 0*
Time delay for throttle timed operation,
“F”
Glow Plug Timer
0-9, 0*
Delay time for starter activation
“H”
Start Duration Timer
0-9, 5*
Maximum time for starter cranking
“J”
Emergency Power Duration Time
0-d, 8*
Maximum time for Emergency Power operation
“L”
Diagnostic display On/Off
0*
Diagnostic Display Off
1
Diagnostic Display On
“o”
Auto Stop Pressure Delay Timer
3-d, 7*
Pressure Sender delay time out when in Auto Stop Mode
“P”
Pressure Switch Descriptor
0*
Normally open and ground signal indicates pressure present.
1
Normally closed and ground signal indicates NO pressure.
2
Normally open and positive signal indicates pressure present.
3
Normally closed and positive signal indicates NO pressure,
Table 3. Programmable parameters and settings.
*
Denotes Factory Setting. † See timer notes Appendix VI
Value
Delay Time
Value
Delay Time
Value
Delay Time
0
No delay / timeout
5
10 seconds
A
1 minute
1
1 second
6
15 seconds
b
2 minutes
2
2 seconds
7
20 seconds
C
3 minutes
3
3 seconds
8
30 seconds
d
4 minutes
4
5 seconds
9
45 seconds
Table 4. Programmable Delay Timer Values