APPEnDIx II. ConnECTIon TABLES
Ignition relay on SST-4 is “Normally Closed”. If power is not supplied to the board, the
ignition circuit will be closed and the ignition function will not be interrupted.
The SST-4 hour meter can be triggered either by the MASTER signal or the SPARE signal
on J1 Pin 1. This is user-programmable, as described in Section 5. PROGRAMMING.
T1 and T2 are identical, except T1 controls Relay 1 and T2 controls Relay2.
1.
2.
3.
T1 Pin
Label
Function
Vehicle
Wire Label
1
RLY1 N.C.
Common to throttle control relay one, Normally Closed
Throttle Circuit
RLY 1 NC
2
RLY1 N.O.
Common to throttle control relay one, Normally Open
Throttle Circuit
RLY 1 NO
3
RLY1 N.C.
Output from throttle control relay one, Normally Closed
Throttle Circuit
RLY 1 NC
4
RLY1 N.O.
Output from throttle control relay one, Normally Open
Throttle Circuit
RLY 1 NO
T1 & T2 Connections
TB1
Pin#
Label
Function
Vehicle
Wire Label
(typical)
1
GND
Ground (Use negative battery connection, not
vehicle chassis.)
Battery (-)
GND
2
START OUT
Supplies power to starter when relay is enabled
Output from key
“Start”
STARTER
3
VBAT
Su12V to board in normal operation
Battery (+)
VBAT
4
AUx IN
Auxiliary input. May be used for Emergency
Power or other user defined function.
E-Power battery
AUx BAT
5
AUx OUT
Auxiliary output supplies high current output to
E-pump or other function when relay is enabled E-Pump
AUx OUT
6
IGN IN
Ignition input signal.
key side of ignition
splice
IGN IN
7
IGN OUT
Ignition output
ECM side of
ignition splice
IGN OUT
TB1 Connections
J1#
Label
Function
Vehicle
Wire Label
1
PRESSURE
Pressure sensor trigger input.
Engine oil or PTO
hydraulic fluid sensor.
PRESSURE
2
AUx
TRIGGER
Triggers Auxiliary circuitry used for E-
power
E-Pump switch
AUx TRIG
3
MASTER
Enables SST-4 operation and triggers on-
board hour meter
Master enable switch
MASTER POS
4
THROTTLE
Triggers throttle circuitry on SST-4 board
Bucket Throttle switch
THROTTLE
5
START/STOP
Triggers Start/Stop circuitry on SST-4
board
Bucket Start/Stop
switch
START TRIG
6
GROUND
Ground (Use negative battery connection,
not vehicle chassis.)
Battery (-)
GND
J1 Connections
T1 Pin
Label
Function
Vehicle
Wire Label
1
RLY2 N.C.
Common to throttle control relay two, Normally Closed
Throttle Circuit
RLY 2 NC
2
RLY2 N.O.
Common to throttle control relay two, Normally Open
Throttle Circuit
RLY 2 NO
3
RLY2 N.C.
Output from throttle control relay two, Normally Closed
Throttle Circuit
RLY 2 NC
4
RLY2 N.O.
Output from throttle control relay two, Normally Open
Throttle Circuit
RLY 2 NO
1
2
3
4
5
6
7
TB1
6
3
J1
4
1
4
3
4
3
1
T1
2
T2
2
1
J1 INPUTS
TBI
T1
T2
PIN FUNCTION
TSP
FUNCTION
PIN FUNCTION
PIN FUNCTION
1
PRESSURE
1
GROUND
1
RLY1 NORM.CLOSED
1
RLY2 NORM.CLOSED
2
AUX TRIG
2
START OUT
2
RLY1 NORM.OPEN
2
RLY2 NORM.OPEN
3
MASTER
3
MAIN POWER (VBAT)
3
RLY1 NORM.CLOSED
3
RLY2 NORM.CLOSED
4
THROTTLE
4
AUX IN
4
RLY1 NORM.OPEN
4
RLY2 NORM.OPEN
5
START/STOP
5
AUX OUT
6
GROUND
6
IGNITION IN
7
IGNITION OUT