1. Product Summary 

WR-1004MLD

 

outdoor optical node can be configured 2 forward path optical receiver modules, 2 

return  path  optical  transmitter  modules,  1  Ethernet  transponder  module  and  2  switching  power 
supply modules at most. Adopts advanced optical AGC technology, the adjustment of output level 
and output slope both adopt fixed inserter. Add LED nixie tube display function, can output 4-way 
forward path signal (

108dBμV) at most. 

 

2. Performance Characteristics 

 

Forward path optical receiving part adopts advanced optical AGC technology, the input optical 
power range extended to -8

+2dBm. 

 

Forward  path  optical  receiving  part:  RF  operating  bandwidth  extended  to  1GHz,  each  way 
maximum output level up to 114dBμv. 

 

The  attenuation  and  equilibrium  control  circuit  adopts  fixed  inserter,  and  achieve  remote 
monitoring by NMS. 

 

RF amplifier part adopts quick plug modular design, can quickly replace RF amplifier module 
without dismantling the RF cable connector. 

 

Built-in perfect condition monitoring circuit, and support Ethernet transponder. 

 

Built-in tri-state gate switch circuit in the return path. Three states passthrough, -6dB and OFF 
can be remote set by network management responder. 

 

Reserved  C-CMTS  forward  path  and  return  path  RF  interface,  support  DOCSIS  EOC 
networking scheme. 

 

3. Technique Parameter 

3.1 Link Testing Conditions 

The performance parameters of this manual according to the measuring method of GY/T 194-2003 
< Specifications and methods of measurement on optical node used in CATV systems >, and tested 
in the following conditions. 
1.

 

Forward  optical  receive  part:  with  10km  standard  optical  fiber,  passive  optical  attenuator  and 

standard optical transmitter composed the  testing link. Set 59 PAL-D analog TV channel signal at 
range of 45/87MHz

550MHz under the specified link loss. Transmit digital modulation signal at 

range  of  550MHz

862/1003MHz,  the  digital  modulation  signal  level  (in  8  MHz  bandwidth)  is 

10dB  lower  than  analog  signal  carrier  level.  When  the  input  optical  power  of  optical  receiver  is 
-1dBm,  the  RF  output  level  is  108dBμV

 

independent  output,  with  8dB  output  tilt,  measure  the 

C/CTB, C/CSO and C/N.   
2.

 

Return optical transmit part: Link flatness and NPR dynamic range are the link indexes which 
is composed of return path optical transmitter and optical receiver.   

Note: 

When the rated output level is the system full configuration and the receiving optical power is 

-1dBm, equipment meets the maximum output level of link index. When the system configuration 
degrade  (that  is,  the  actual  transmission  channels  reduce),  the  output  level  of  equipment  will  be 
increased. 

Friendly  Notice

:  Suggest  you  setting  the  RF  signal  to  6~9dB  slope  output  in  the  practical 

engineering application to improve the nonlinear index (behind the node) of the cable system.

   

Summary of Contents for WR-1004MLD

Page 1: ... do o oo o or r r O O Op p pt t ti i ic c ca a al l l N N No o od d de e e O O Op p pe e er r ra a at t ti i io o on n n a a an n nd d d M M Ma a ai i in n nt t te e en n na a an n nc c ce e e M M Ma a an n nu u ua a al l l 2 20 01 16 6 1 1 V Ve er rs si io on n 1 1 ...

Page 2: ...DOCSIS EOC networking scheme 3 Technique Parameter 3 1 Link Testing Conditions The performance parameters of this manual according to the measuring method of GY T 194 2003 Specifications and methods of measurement on optical node used in CATV systems and tested in the following conditions 1 Forward optical receive part with 10km standard optical fiber passive optical attenuator and standard optica...

Page 3: ...B 0 75 Rated Output Level dBμV 108 when the optical AGC control range is 2 8 Max Output Level dBμV 114 when the optical AGC control range is 2 5 Output Return Loss dB 85 550MHz 16 550 1000MHz 14 Redundant Receiver Isolation dB 75 Output Impedance Ω 75 Return Part Optical Parameters Optical Transmit Wavelength nm 1310 10 1550 10 or specified by the user Laser Type DFB or FP laser Output Optical Pow...

Page 4: ...gain dB 0 1 Port CMTS_US OUT Isolation forward path CMTS_US return path output dB 70 General Performance Power voltage V A AC 150 265 V B AC 35 90 V Feed current through A 10 Operating temperature 40 60 Storage temperature 40 70 Relative humidity Max 95 no condensation Consumption VA 42 Dimension mm 460 L 282 W 175 H 4 Block Diagram 5 Relation Table of Input Optical Power and CNR ...

Page 5: ...WR 1004MLD Outdoor Optical Node Operation and Maintenance Manual 4 ...

Page 6: ...WR 1004MLD Outdoor Optical Node Operation and Maintenance Manual 5 6 Function Display and Operating Instruction ...

Page 7: ...wer module 1 socket 13 220Vac input 14 The RF output test port 20dB of forward path optical receiver modules 15 RF output of forward path optical receiver modules 16 The RF input interface of return path optical transmit modules 1 17 The RF input interface of return path optical transmit modules 2 18 Power 1 fuse 19 Power module 1 20 Power 2 fuse 21 Power module 2 22 Forward path optical receiver ...

Page 8: ...t port 20dB 13 Forward path RF input 14 Port 4 return path input test port 20dB 15 Return path RF output 2 16 Return path RF output 1 17 Mode setting and attenuation jumper 18 Return path components 19 Port 3 return path input test port 20dB 20 Port 2 return path input test port 20dB 21 Port 2 forward path output test port 20dB 22 Port 2 23 Port 2 feed fuse 24 AC60V independent feed port 25 Handle...

Page 9: ...t the computer and responder can be direct connected and change the computer IP to 192 168 1 XXX XXX is any number from 0 to 255 except 168 start upper computer network management software then search the device and log in 3 Right click device icon and choose modify the device IP 4 Enter new IP address gateway and subnet mask 5 Click modify then exit it is done There will show new IP address and g...

Page 10: ...h 4 The C N index of system link signal is too low 1 Check the received optical power of the optical contact point and make appropriate adjustments to make it in the specified range 2 Improve the optical received power of the optical contact point by cleaning the optical fiber connector or adapter etc methods Specific operation methods see Clean and maintenance method of the optical fiber connecto...

Page 11: ...the optical fiber connector or the optical fiber connector has been polluted by the dust or dirt Now introduce some common clean and maintenance methods of the optical fiber active connector 1 Carefully pull off the optical fiber active connector from the adapter The optical fiber active connector should not aim at the human body or the naked eyes to avoid accidental injury 2 Wash carefully with g...

Page 12: ... unavoidable environment reasons we will responsible maintenance but ask suitable material cost 2 When the equipment breaks down immediately contact local distributor or directly call our technical support hotline 86 0571 82576002 18967160936 3 The site maintenance of the fault equipment must be operated by professional technicians to avoid worse damage Special notice If the equipment has been mai...