ES - Upload a specific SES file
Upload the configuration in the SES file to ES without changing anything in the file.
ES - Get OTAP Capcodes
Read Over The Air Programming Capcodes from the PDT3000. The OTAP capcodes which the unit had can be
displayed on the OTAP option window if this reading operation was successful.
The Capcodes Window
This window is used to set the cap codes (addresses) and the output settings for each cap code.
Adding Capcodes (Addresses)
1. Enter a new CAP code by clicking on the "New" Button.
2. Enter the new CAP code in the "Capcode" box and the name in the name box below. i.e., 1234567 TEST
CAP. The name is just an identifier and is not compulsory.
3. If a range of cap codes is required then select the first cap code and the range that you wish to monitor e.g
entering cap code 1000000 and a range of 50 will monitor cap codes 1000000 to 1000050.
4. Set each of the desired outputs individually for each cap code by highlighting the cap code in the Left hand
window and then selecting the outputs on the Right.