SERVICE MANUAL & I.C.A. FOR THE 7000 AMPHIBIOUS FLOATS
Revision G Page 91 of 102 P/N 1004646 Doc. No. W7001-24-01
OPTIONALLY REMOVED FLOAT KIT ITEMS
(the following items may be removed when the aircraft is removed from
floats, but it is recommended for ease of float reinstallation that they are
left in place
MECHANIC
INSP.
THIS IS INTENDED AS A GENERAL GUIDE. EACH INSTALLATION MAY HAVE
SUBTLE DIFFERENCES. ALWAYS USE THE INSTALLATION DRAWINGS AS
THE FINAL REFERENCE. ALL WORK SHOULD BE DONE BY CERTIFIED
AIRCRAFT TECHNICIANS.
Hydraulic Power Pack (in tailcone)
1. Disconnect, cap, and secure hydraulic lines that run forward under the floor (3
lines)
2. Disconnect and secure electrical power lines and gear position connector from
power pack
3. Unbolt power pack mounting plate from installed hardpoints and remove
4. Pull and secure electric motor breakers on fwd breaker panel
Hand Operated Emergency Hydraulic Pump and Water Rudder Retract
Handle
1. Unbolt Pedestal from floor
2. Disconnect, cap, and secure hydraulic lines under the floor (3 lines)
3. Disconnect water rudder retract cable, coil, and secure under floor
4. Install appropriately sized bolts in pedestal attachment locations
Gear Selector
1. Unscrew selector face and remove from panel
2. Disconnect gear position connector and secure behind panel
3. Install Filler plate in panel
Emergency Trim Timer Override System (ETTOS)
1. Remove Guarded Switch from panel
4. Follow wires from override switch to trim timer connection
5. Unplug override switch connectors and reconnect trim timer using existing
connectors
6. Plug Hole in panel left from override switch
7. Remove "Emergency Aileron Trim Timer Bypass" Placard