*If existing grease cannot be identified you must lubri-flush all float grease fittings until visibly exhausting all old
grease and new grease is coming out. Additionally if you cannot determine existing grease in wheel bearings,
completely clean and repack bearings with new grease.
As general inspection guidelines, each of the following areas should be inspected for their own unique attributes:
Movable Parts
For lubrication, servicing, security of attachment, binding, excessive wear, safetying, proper operation, proper
adjustment, correct travel, cracked fittings, security of hinges, defective bearings, cleanliness, corrosion,
deformation, sealing, and tension.
Fluid Lines and Hoses
For leaks, cracks, dents, kinks, chafing, security, corrosion, and deterioration.
Metal Parts
For security of attachment, cracks, metal distortion, broken welds, corrosion, condition of paint, and any other
apparent damage.
Wiring
For security, chafing, burning, defective insulation, loose or broken terminals, corroded terminals.
Bolts in Critical Area
For corrosion, correct torque when installed, or when visual inspection indicates a need for a torque check.
Nut torque should be applied depending on the hardware application, unless the torque is specified for a certain
joint in this manual or installation drawings.
**A Torque of 80% should be used when Tef-Gel is applied to the bolt.